Electrochemical Characterization of Silicon-Based Gold Microband Electrode Array and its Application for Labelless T-2/HT-2 Toxin Immunosensing

Author:

Said Nur Azura Mohd1,Herzog Gregoire2,Twomey Karen3,Ogurtsov Vladimir I.3

Affiliation:

1. Malaysian Agricultural Research and Development Institute (MARDI)

2. CNRS-Université de Lorraine

3. University College Cork

Abstract

Microelectrode arrays (MEAs) are gaining interest in electroanalysis owing to its distinctive voltammetry properties compared to its macro counterparts. Among the MEAs widely fabricated and studied are microdisc array and microband array. We report here the microfabrication of 10 μm microband array (number of band in an array, N=17) and its application in labelless impedimetric sensing of T-2/HT-2 toxin. The microband array has recess depth (i.e. Si3N4 passivation thickness) of 200 nm. Upon fabrication, the device was first characterized via visual inspection and electrochemical analysis. Cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) studies were performed in 1 mM ferrocenecarboxylic acid (FCA) in 0.01 M PBS, pH 7.4. At scan rate of 100 mv s-1, cyclic voltammogram for the microband array exhibited a slight peak-shaped CV; and was found to be scan-rate dependent. Experimental limiting current of the microband array (529±7 nA) was slightly lower compared to the calculated theoretical current (632 nA) indicating mixed diffusion profile of the microband array. The device was then employed in immunosensor construction for T-2/HT-2 toxins detection. T-2 mycotoxin and its metabolite (HT-2), are target of concern in the biosensing application due to its lethal toxicity and prominent presence in EU grains industry. Surface functionalization for anti-T-2 monoclonal antibody (mAb) immobilization was first achieved via surface hydroxylation with plasma cleaning and piranha solution treatment, followed by (3-Aminopropyl) triethoxysilane (APTES) silanization and 15 minutes pre-incubation with various concentrations of anti-T-2 toxin mAb in EDC/NHS mixture. The optimal concentrations for anti-T-2 toxin mAb immobilization on the microband array surface was determined at 0.75 mg mL-1. Based on the calibration curve developed in buffer solution system, the functionalized microband array was proven sensitive as it was able to detect T-2/HT-2 toxin at low dynamic working range (0-25 ppb) and limit of quantitation (LOQ) achieved at 4.89 ppb.

Publisher

Trans Tech Publications, Ltd.

Subject

Mechanical Engineering,Mechanics of Materials,Condensed Matter Physics,General Materials Science

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. DNA METİLASYONUNA NEDEN OLAN MİKOTOKSİNLERİN ELEKTROANALİTİK YÖNTEMLERLE ANALİZİ;Ankara Universitesi Eczacilik Fakultesi Dergisi;2024-08-12

2. Fabrication and Characterisations of Recessed Microdisc Electrode Array for Immunosensor Detection of T-2/HT-2 Mycotoxin;2022 4th International Conference on Smart Sensors and Application (ICSSA);2022-07-26

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3