Affiliation:
1. Universiti Teknologi Malaysia
Abstract
Vibration monitoring is widely recognized as an effective tool for the detection and diagnosis of incipient failures of gas turbines. This paper presents a review of vibration based methods for turbine blade faults. Methods typically involved analysis of blade passing frequencies, and extraction of dynamic signals from the measured vibration response. This includes frequency analysis, wavelet analysis, neural networks and fuzzy logic and model based analysis. The literature reviewed showed that vibration could detect most types of blade faults on the basis that dynamic signals are correctly extracted using the most appropriate signal processing method.
Publisher
Trans Tech Publications, Ltd.
Reference33 articles.
1. N. Goel, a Kumar, V. Narasimhan, a Nayak, and a Srivastava: Health risk assessment and prognosis of gas turbine blades by simulation and statistical methods. Canadian Conference on Electrical and Computer Engineering, Niagara Falls. May 2008, pp.001087-001092.
2. Meher-Homji, C.B. (1995b). Blading Vibration and Failures in Gas Turbines: Part B, Compressor and Turbine Airfoil Distress. ASME paper no. 95-GT-419.
3. M Salman LEONG: Field Experiences of Gas Turbines Vibrations -A Review and Case Studies. Journal of System Design and Dynamics. Vol. 2, No. 1 (2008), pp.24-35.
4. Simmons, H.R. (1986). A Non-Intrusive Method for Detecting HP Blade Resonance. ASME Paper No. 86-JPGC-Pwr-36.
5. Simmons, H.R. (1987). Non-Intrusive Detection of Turbine Blade Resonance. Third EPRI Conference on Incipient Failure Detection in Power Plants, Philadelphia, March 10–12, (1987).
Cited by
22 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献