Abstract
The influence of the bond pattern on the in-plane limit strength of masonry is analyzed through a simplified procedure based on the application of the safe theorem of limit analysis to the unit cell that generates the whole masonry by periodic repetition. The limit strength domains of running bond, English bond and herringbone bond masonry are obtained with different orientations of the mortar bed joints with respect to the principal directions of the average stress. The effects of different brick geometries are analyzed and comparisons between strength properties of different masonry patterns are made.
Publisher
Trans Tech Publications, Ltd.
Reference14 articles.
1. Cowan H. J., A History of Masonry and Concrete Domes in Building Construction, Building and Environment, 12, 1977, 1-24.
2. Page A.W., The biaxial compressive strength of brick masonry, Proc. Inst. Civil Engineering, 3, 1981, 893 –906.
3. Page A.W., The strength of brick masonry under biaxial tension-compression, Int. J. Masonry Constructions, 3, 1983, 26-31.
4. Suquet P., Analyse limite et homogeneisation, Comptes Rendus de l'Academie des Sciences—Series IIB—Mechanics, 296, 1983, 1355–1358.
5. Suquet P., Elements of homogenization for inelastic solid mechanics. In Homogenization Techniques for Composite Media. Lecture Notes in Physics 272 (Edited by Sanchez-Palencia and A. Zaoui), 193-278. Springer, New York.
Cited by
9 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献