Affiliation:
1. Dalian Maritime University
2. University of Waterloo
Abstract
Wear debris in hydraulic oil causes most of the faults of hydraulic system and is also an important information carrier, so it is essential to check the condition of wear debris in hydraulic oil. On the basis of inductive principle and microfluidic chip technology, the design of a microfluidic chip of oil detection is presented in this paper. the relation between coil geometry parameters and inductive change of planar inductor are analyzed through the related experimental statistics, the result being that when the ferrous metallic particle flows through planar inductor, the measured inductance variation increases with the number of turns and decreases with the coil line width.
Publisher
Trans Tech Publications, Ltd.
Reference10 articles.
1. Li Du, Jiang Zhe: Tribology International Vol. 44 (2011), pp.175-179.
2. Rao BK: Handbook of condition monitoring (Elsevier Advanced Technology, UK 1996).
3. Li Du, Jiang Zhe, Joan Carletta, Robert Veilette: Microfluid Nanofluid Vol. 9 (2010), pp.1241-1245.
4. Hongpeng Zhang,Chan Hee Chon, Xinxiang Pan, Dongqing Li: Microfluid Nanofluid Vol. 7 (2009), p.739–749.
5. Yongxin Song, Hongpeng Zhang, Chan Hee Chon, Shu Chen, Xinxiang Pan and Dongqing Li: Analytica Chimica Acta Vol. 681 (2010), pp.82-86.
Cited by
16 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献