Affiliation:
1. CNR-IMM Sezione di Bologna
Abstract
In this work under-mask penetration of Al+ ions implanted in 4H-SiC is investigated by computer simulation based on the Monte-Carlo binary collision approximation (MC–BCA). Results indicate that a small fraction of ions, implanted normal to a (0001) 4H-SiC wafer (8° off-axis towards the {11-20}), is scattered and become channeled in the <1120> directions perpendicular to the <0001> axis. Due to this phenomenon, doped regions with concentration ≤ 10− 4 of the peak value, may extend laterally for a few µm below the edge of a SiO2 mask.
Publisher
Trans Tech Publications, Ltd.
Subject
Mechanical Engineering,Mechanics of Materials,Condensed Matter Physics,General Materials Science
Reference8 articles.
1. J. Wong-Leung, M. Janson and B. Svensson, J. Appl. Phys, Vol. 93 (2003), p.8914.
2. E. Morvan, N. Mestres, J. Pascual, D. Flores, M. Vellvehi and J. Rebollo, Mat. Sci. and Eng. B, Vol. 61–62 (1999), p.373.
3. K. Mochizuki, N. Kameshiro, H. Onose and N. Yokoyama IEEE Trans. Electron Devices, Vol. 56 (2009), p.992.
4. E. Albertazzi and G. Lulli, Nucl. Instrum. Meth. B, Vol. 120 (1996), p.147.
5. G. Lulli, E. Albertazzi, M. Bianconi and R. Nipoti, Nucl. Instrum. Meth. B, Vol. 148 (1999), p.573.
Cited by
4 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献