Comparative Analysis of Changes in the Desmal and Chondral Structures of Spinal Motion Segment at Various Methods for Posterior Spine Fixation in Experiment

Author:

Krivoshein A. E.1,Konev V. P.1,Kolesov S. V.2,Byval’tsev V. A.3,Kaz’min A. I.2

Affiliation:

1. Omsk State Medical University, Omsk

2. N.N. Priorov National Medical Research Center of Traumatology and Orthopaedics, Moscow

3. Irkutsk State Medical University, Irkutsk, Russia

Abstract

Purpose:to elaborate the criteria for the assessment of the degree of spinal motion segment degradation at various methods for posterior spine fixation in experiment.Material and methods. The study included mongrel dogs with body mass of 12±1.5 kg aged 21±3 months. Transpedicular lumbar spine fixation was performed with either rigid titanium alloy rods (1st group, n=5) or dynamic nitinol rods (2nd group, n=5). X-ray examination and morphologic study of the structural elements of spinal motion segment (SME) were performed to all animals in 3, 6, 12, 18 and 24 months after surgery.Results. Functional examination showed that in both groups the range of motion made up 18±1.2° preoperatively. In the 1st group of animals the range of motion in the operated SME made up 0±0.03°. In the second group the range of motion was preserved throughout the experiment and averaged 15±1.3° that made up 78.9% of the preoperative range. In both groups the disc height at the fixation level was constant throughout the experiment and made up 0,3±0.003 cm pre- and postoperatively. Obtained roentgenologic and morphologic data indicated that posterior dynamic spine fixation with nitinol rods ensured more balanced distribution of loads on the supportive elements of the construction and enabled prevent the development of the adjacent segments degeneration. Based on the study results the criteria for the assessment of the degree of the facet joints and discs degradation were formulated.

Publisher

ECO-Vector LLC

Subject

General Medicine

Reference10 articles.

1. Martynova M.A. Comparative analysis of surgical treatment outcomes in patients with instability of lumbar spine motion segment using transforaminal lumbar in-terbody fusion and (TLIF) direct lumbar interbody fusion (DLIF). Cand. med. sci. Diss. Moscow; 2016 (in Russian)].

2. Simonovich A.E. Use of DYNESYS instrumentation for the dynamic stabilization of degenerative lumbar spine. Khirurgiya pozvonochnika. 2004; 1: 60-6 (in Russian)].

3. Makirov S.K., Yuz A.A., Dzhakharov M.T., Gusev S.S. Modern opportunities of posterior dynamic stabilization of the spine to prevent adjacent segment syndrome: review of the literature. Khirurgiya pozvonochnika. 2015; 12 (1): 46-62 (in Russian)].

4. Makarov S.N. Influence of the methods for the correction of spinal cord root microcirculation disturbance and various methods of fixation on the outcomes of lumbar osteochondrosis surgical treatment. Cand. med. sci. Diss. Moscow; 2014 (in Russian)].

5. Simonovich A.E., Mar- kin S.P., Nuraliev Kh.A., Snezhkov I.I. The influence of dynamic fixation on lumbar segmental mobility. Khirurgiya pozvonochnika. 2008; 4: 30-6 (in Russian)].

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3