Evaluation of a New Powerful Bone-Anchored Hearing System: A Comparison Study

Author:

Bosman Arjan J.,Snik Ad F.M.,Hol Myrthe K.S.,Mylanus Emmanuel A.M.

Abstract

Background: The recent introduction of digital hearing aid technology for bone-conduction devices employing percutaneous stimulation may be beneficial for patients with conductive and mixed hearing loss and single sided deafness. Purpose: Performance of a recently released sound processor for bone-anchored implants, the Ponto Pro Power from Oticon Medical (bone-conduction device 2 [BCD2]), was compared with that of the Baha Intenso from Cochlear (bone-conduction device 1 [BCD1]). Research Design: Direct comparison of the subject's own device (BCD1) with the new device (BCD2) was examined in a nonrandomized design. Subjects were initially tested with BCD1. BCD2 was tested after a 4 wk acclimatization period. Study Sample: Eighteen subjects with mixed hearing loss and with at least 4 mo experience with BCD1 completed the study. Mean air-conduction and bone-conduction thresholds averaged across the frequencies of 500, 1000, 2000, and 4000 Hz were 73.9 and 34.2 dB HL, respectively. Data Collection and Analysis: Performance of the two devices was evaluated objectively by measuring aided free-field thresholds, speech perception in quiet, and speech perception in noise. A subjective evaluation was carried out with the Abbreviated Profile of Hearing Aid Benefit (APHAB) (Cox and Alexander, 1995) and the Speech, Spatial and Qualities of Hearing Scale (SSQ) questionnaire (Gatehouse and Noble, 2004). In addition, user experiences, user satisfaction, and device preference were obtained via proprietary questionnaires. Statistical significance was established with analysis-of-variance (ANOVA) and paired t-statistics with Bonferroni correction. Results: Aided free-field thresholds and speech reception thresholds (SRTs) in quiet were not statistically significantly different for either device (p > 0.05). In contrast, SRTs in noise were 2.0 dB lower (p < 0.001) for BCD2 than for BCD1. APHAB questionnaire scores on all subscales provided statistically significantly greater benefit (p < 0.05) for BCD2 than for BCD1. Also, with the SSQ most items in the speech and sound quality domain were significantly more favorable (p < 0.05) for BCD2 than for BCD1. Finally, all subjects preferred BCD2 over BCD1 with 14 subjects reporting a strong preference and four subjects an average preference for the digital signal processing provided by BCD2 over previous technology provided by BCD1.

Publisher

Georg Thieme Verlag KG

Subject

Speech and Hearing

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3