Effects of Long-Term Use of a Cochlear Implant on the Electrically Evoked Compound Action Potential

Author:

Brown Carolyn J.,Abbas Paul J.,Etler Christine P.,O'Brien Sara,Oleson Jacob J.

Abstract

Background: Since the early 1990s, it has been possible to measure electrically evoked compound action potentials (ECAPs) from Nucleus cochlear implant users. Recording the ECAP does not require active participation by the subject, and the recordings are not adversely affected by attention or sleep, making this response an ideal tool for monitoring long-term changes. Previous research from our laboratory (Hughes et al, 2001) has shown that ECAP thresholds and slope of the ECAP growth functions are relatively stable over time. However, this conclusion was based on results obtained from a fairly limited number of study participants, each of whom used the Nucleus CI24M cochlear implant and were followed for less than two years. Purpose: To evaluate the effect of long-term use of a cochlear implant on ECAP thresholds and slope of the ECAP input/output function for both pediatric and adult cochlear implant recipients. Research Design: A longitudinal study that describes how ECAP thresholds and growth functions change over a period of 96 mo following initial activation. Changes over time in ECAP threshold and slope of the ECAP growth function were analyzed, and effects of the subject's age, type of CI (cochlear implant), and stimulating electrode are included in the analysis. Study Sample: 134 Nucleus CI users participated in this study. All were profoundly deaf. This subject pool included 84 individuals (40 adults and 44 children) who used the Nucleus CI24M cochlear implant and 50 individuals (21 adults and 29 children) who used the Nucleus CI24R cochlear implant. Data Collection and Analysis: Electrodes 5, 10, 15, and 20 were stimulated, and ECAP growth functions were measured for each subject at regular intervals following the initial activation of the device. Results: Small increases in mean ECAP thresholds were observed for both pediatric and adult CI users between an “early” visit that occurred within 3–6 mo following hookup and a “late” visit that occurred 4.8–6 yr later. For adults, the average increase in ECAP threshold was 3.94 CL (clinical programming units for Nucleus CIs). For children, the average increase was 4.16 CL. These differences, while small, were statistically significant. Slope of the ECAP growth functions measured over the same time interval did not change significantly. On average, pediatric CI users had ECAP thresholds that were 4–5 CL units higher than the adult CI recipients. The most striking outcome from this study, however, was the finding that when compared with postlingually deafened adults, pediatric CI users had ECAP growth functions that were substantially steeper. The differences between the results obtained from children and those obtained from adults were statistically significant and largely independent of device type or stimulating electrode. Conclusion: Results from this study show ECAP thresholds and growth functions to change very little over a 5–6 yr observation interval suggesting that long-term use of a CI is not likely to have a significant negative impact on the response of the peripheral auditory system. Pediatric Cl users were shown to have, on average, higher ECAP thresholds and steeper ECAP growth functions than postlingually deafened adult CI users. This finding suggests potential differences between the two patient populations either in terms of the current fields within the cochlea or the effective distance between the stimulating electrode and the stimulable neural tissue.

Publisher

Georg Thieme Verlag KG

Subject

Speech and Hearing

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3