Four-year results of a prospective single-arm study on 200 semi-constrained total cervical disc prostheses: clinical and radiographic outcome

Author:

Meisel Hans-Jörg1,Jurák Lubomír2,Antinheimo Jussi3,Arregui Ricardo4,Bruchmann Bernhard5,Čabraja Mario6,Caroli Fabrizio7,Kroppenstedt Stefan8,Kryl Jan9,Pohjola Juha3,Shackleford Ian10,Sola Steffen11,Stosberg Peter1,Stulik Jan9,Woiciechowsky Christian12,Suchomel Petr2

Affiliation:

1. Department of Neurosurgery, BG Clinic Bergmannstrost, Halle, Germany;

2. Neurocentre, Regional Hospital Liberec, Czech Republic;

3. Department of Neurosurgery, University of Helsinki, Finland;

4. Neurosurgical Department, Hospital Maz, Zaragoza, Spain;

5. Spinal Surgery, Katholisches Klinikum Koblenz, Germany;

6. Zentrum für Wirbelsäulenchirurgie, Vivantes Auguste-Viktoria-Klinikum, Berlin, Germany;

7. Neurosurgery, “Regina Elena” National Cancer Institute, Rome, Italy;

8. Abteilung für Wirbelsäulenchirurgie, Sana Kliniken Sommerfeld, Kremmen, Germany;

9. Center for Spine Surgery, Motol University Hospital, Prague, Czech Republic;

10. Spinal Surgery, Warrington District General Hospital, Warrington, United Kingdom; and

11. Department of Neurosurgery, University of Rostock, Germany; and

12. Neurosurgery and Spine Surgery, Spine Center Berlin, Germany

Abstract

OBJECTIVE Recent studies have described encouraging outcomes after cervical total disc replacement (cTDR), but there are also critical debates regarding the long-term effects of heterotopic ossification (HO) and the prevalence of adjacent-level degeneration. The aim in this paper was to provide 4-year clinical and radiographic outcome results on the activ C disc prosthesis. METHODS A total of 200 subjects underwent single-level activ C (Aesculap AG) implantation between C-3 and C-7 for the treatment of symptomatic degenerative disc disease. Clinical and radiographic assessments were performed preoperatively, intraoperatively, at discharge, and again at 6 weeks, 6 months, 1 year, 2 years, and 4 years. Radiographic evaluations were done by an independent core laboratory using a specific software for quantitative motion analysis. RESULTS Neck Disability Index (NDI) and visual analog scale (VAS) score for neck and arm pain decreased significantly from baseline to the 4-year follow-up. The mean improvement for NDI was 20, for VAS severity and frequency of neck pain 26.4 and 28, and for VAS severity and frequency of arm pain 30.7 and 35.1, respectively. The neurological situation improved for the majority of patients (86.4%); 76.1% of cases were asymptomatic. Subsequent surgical interventions were reported in 7% of the cases, including device removals in 3%. In 2.5% a subsidence greater than 3 mm was recorded; 1 of these cases also had a migration greater than 3 mm. No device displacement, expulsion, disassembly, loose or fractured device, osteolysis, or facet joint degeneration at the index level was observed. Segmental lordotic alignment changed from −2.4° preoperatively to −6.2° at 4 years, and postoperative height was maintained during the follow-up. Advanced HO (Grade III and IV) was present in 27.1% of the cases; 82.4% showed segmental mobility. A progression of radiographic adjacent-segment degeneration occurred in 28.2%, but only 4.5% required surgical treatment. CONCLUSIONS The activ C is a safe and effective device for cervical disc replacement confirming the encouraging results after cTDR. Clinical trial registration no.: NCT02492724 (clinicaltrials.gov)

Publisher

Journal of Neurosurgery Publishing Group (JNSPG)

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3