Clinical use of a frameless stereotactic arm: results of 325 cases

Author:

Golfinos John G.,Fitzpatrick Brian C.,Smith Lawrence R.,Spetzler Robert F.

Abstract

✓ The viewing wand is a frameless stereotactic arm that can be used in conjunction with computerized tomography (CT) or magnetic resonance (MR) imaging to provide image-based intraoperative navigation. The authors report a series of 325 cases in which the viewing wand was used and evaluated for its utility, ease of integration into the standard surgical setup, reliability, and real-world accuracy. The use of the system was associated with minimal additional effort or time spent in setting up the procedure as long as a trained technician performed the data transfer and reconstruction. The viewing wand was used in 165 cases in conjunction with CT and 145 cases with MR imaging. The system was reliable, achieving a useful registration in 310 of 325 cases (95.4%). Fiducial-based registration was more accurate than an anatomical landmark—surface fit algorithm method of registration (mean 2.8 vs. 5.6 mm error, respectively, for CT; and mean 3.0 vs. 6.2 mm for MR imaging). The actual error of the system in estimating the position of the probe tip just after registration was judged by the operating surgeon to be less than 2 mm in 92% of MR imaging cases and in 82% of CT cases, between 2 and 5 mm in 7% of MR imaging and 17% of CT cases, and greater than 5 mm in less than 1% of MR imaging and 1.2% of CT cases. The accuracy of the system degraded during the operation, so that by the third evaluation the error was estimated to be less than 2 mm in 77% of MR imaging and 62% of CT cases. Overall, the viewing wand was found to be reliable and accurate. This real-world accuracy was sufficient for a broad range of applications including glioma resection, cerebrospinal fluid shunting procedures, resection of small subcortical masses, and temporal lobe resection. The system is a useful navigational aid that allows a direct approach to intracranial pathology without the drawbacks of application and the limitations of a stereotactic frame.

Publisher

Journal of Neurosurgery Publishing Group (JNSPG)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3