Freehand screw insertion technique without image guidance for the cortical bone trajectory screw in posterior lumbar interbody fusion: what affects screw misplacement?

Author:

Ishii Masayoshi1,Ohnishi Atsunori1,Yamagishi Akira1,Ohwada Tetsuo1

Affiliation:

1. Department of Orthopaedic Surgery, Kansai Rosai Hospital, Amagasaki, Hyogo, Japan

Abstract

OBJECTIVE Cortical bone trajectory (CBT) screw insertion using a freehand technique is considered less feasible than guided techniques, due to the lack of readily identifiable visual landmarks. However, in posterior lumbar interbody fusion (PLIF), after resection of the posterior anatomy, the pedicles themselves, into which implantation is performed, are palpable from the spinal canal and neural foramen. With the help of pedicle wall probing, the authors have placed CBT screws using a freehand technique without image guidance in PLIF. This technique has advantages of no radiation exposure and no requirement for expensive devices, but the disadvantage of reduced accuracy in screw placement. To address the problem of symptomatic breaches with this freehand technique, variables related to unacceptable screw positioning and need for revisions were investigated. METHODS From 2014 to 2020, 182 of 426 patients with single-level PLIF were enrolled according to the combined criteria of L4–5 level, excluding cases of revision and isthmic spondylolisthesis; using screws 5.5 mm in diameter; and operated by right-handed surgeons. We studied the number of misplaced screws found and replaced during initial surgeries. Using multiplanar reconstruction CT postoperatively, 692 screw positions on images were classified using previously reported grading criteria. Details of pedicle breaches requiring revisions were studied. We conducted a statistical analysis of the relationship between unacceptable (perforations > 2 mm) misplacements and four variables: level, laterality, spinal deformity, and experiences of surgeons. RESULTS Three screws in L4 and another in L5 were revised during initial surgeries. The total rate of unacceptable screws on CT examinations was 3.3%. Three screws in L4 and another in L5 breached inferomedial pedicle walls in grade 3 and required revisions. The revision rate was 2.2%. The percentage of unacceptable screws was 5.2% in L4 and 1.7% in L5 (p < 0.05), whereas other variables showed no significant differences. CONCLUSIONS A freehand technique can be feasible for CBT screw insertion in PLIF, balancing the risks of 3.3% unacceptable misplacements and 2.2% revisions with the benefits of no radiation exposure and no need for expensive devices. Pedicle palpation in L4 is the key to safety, even though it requires deeper and more difficult probing. In the initial surgeries and revisions, 75% of revised screws were observed in L4, and unacceptable screw positions were more likely to be found in L4 than in L5.

Publisher

Journal of Neurosurgery Publishing Group (JNSPG)

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3