Development and validation of a patient face-mounted, negative-pressure antechamber for reducing exposure of healthcare workers to aerosolized particles during endonasal surgery

Author:

Lee Mark1,Rivera-Rosario Hazel T.2,Kim Matthew H.1,Bewley Gregory P.2,Wang Jane2,Warhaft Zellman2,Stylman Bradley3,Park Angela I.4,MacMahon Aoife1,Kacker Ashutosh1,Schwartz Theodore H.5

Affiliation:

1. Department of Otolaryngology–Head and Neck Surgery, Weill Cornell Medicine, New York;

2. Department of Mechanical and Aerospace Engineering, Cornell University, Ithaca; and

3. Environmental Health & Safety,

4. Molecular Biology, and

5. Department of Neurosurgery, Weill Cornell Medicine, New York, New York

Abstract

OBJECTIVE The authors developed a negative-pressure, patient face-mounted antechamber and tested its efficacy as a tool for sequestering aerated particles and improving the safety of endonasal surgical procedures. METHODS Antechamber prototyping was performed with 3D printing and silicone-elastomer molding. The lowest vacuum settings needed to meet specifications for class I biosafety cabinets (flow rate ≥ 0.38 m/sec) were determined using an anemometer. A cross-validation approach with two different techniques, optical particle sizing and high-speed videography/shadowgraphy, was used to identify the minimum pressures required to sequester aerosolized materials. At the minimum vacuum settings identified, physical parameters were quantified, including flow rate, antechamber pressure, and time to clearance. RESULTS The minimum tube pressures needed to meet specifications for class I biosafety cabinets were −1.0 and −14.5 mm Hg for the surgical chambers with (“closed face”) and without (“open face”) the silicone diaphragm covering the operative port, respectively. Optical particle sizing did not detect aerosol generation from surgical drilling at these vacuum settings; however, videography estimated higher thresholds required to contain aerosols, at −6 and −35 mm Hg. Simulation of surgical movement disrupted aerosol containment visualized by shadowgraphy in the open-faced but not the closed-faced version of the mask; however, the closed-face version of the mask required increased negative pressure (−15 mm Hg) to contain aerosols during surgical simulation. CONCLUSIONS Portable, negative-pressure surgical compartments can contain aerosols from surgical drilling with pressures attainable by standard hospital and clinic vacuums. Future studies are needed to carefully consider the reliability of different techniques for detecting aerosols.

Publisher

Journal of Neurosurgery Publishing Group (JNSPG)

Subject

Genetics,Animal Science and Zoology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3