Calvarial slope affecting accuracy of Ghajar Guide technique for ventricular catheter placement

Author:

Park Jaechan12,Son Wonsoo12,Park Ki-Su12,Kim Min Young2,Lee Joomi3

Affiliation:

1. Department of Neurosurgery,

2. Research Center for Neurosurgical Robotic Systems, and

3. Cell & Matrix Research Institute, Kyungpook National University, Daegu, Republic of Korea

Abstract

OBJECT The Ghajar Guide technique is used to direct a ventricular catheter at a 90° angle to the skull surface at Kocher’s point. However, the human calvaria is not completely spherical. Lateral to the sagittal midline, the calvaria slopes downward with individual variation and thereby affects the accuracy of ventricular catheter placement. Accordingly, the authors investigated the accuracy of the orthogonal catheter trajectory using radiographic simulation and examined the effect of the calvarial slope on this accuracy. METHODS A catheter trajectory orthogonal to the skull surface at Kocher’s point and the ideal catheter trajectory to the foramen of Monro were drawn bilaterally on coronal head images of 52 patients with hydrocephalus. The correction angle, the difference between the 2 catheter trajectories, was then measured. Meanwhile, the calvarial slope was measured around Kocher’s point by using a coronal head image. The correlation between the correction angle and factors such as the calvarial slope and bicaudate index was then assessed using a Pearson correlation analysis. RESULTS The ventricular catheter trajectory orthogonal to the skull at Kocher’s point in the patients with hydrocephalus led to a catheter trajectory into the ipsilateral (70.2%) or contralateral (29.8%) lateral ventricles. The correction angles ranged from −3.3° to 16.4° (mean ± SD 5.7° ± 3.7°). In 87 (83.7%) head sides, lateral deviation from the orthogonal trajectory was required to approximate the ideal trajectory, and the correction angle ranged from 2.0° to 16.4° (mean 6.7° ± 2.9°). The calvarial slope in the 104 head sides ranged from 15.6° to 32.5° (mean 24.2° ± 3.1°). Pearson correlation analysis revealed a strong positive correlation (r = 0.733) between the calvarial slope and the correction angle. CONCLUSIONS The accuracy of ventricular catheter placement using the Ghajar Guide technique is affected primarily by the calvarial slope around Kocher’s point. A radiographic analysis of a preoperative coronal head image can be used to estimate the accuracy of ventricular catheter placement and enable adjustment to approximate the ideal catheter trajectory.

Publisher

Journal of Neurosurgery Publishing Group (JNSPG)

Subject

Genetics,Animal Science and Zoology

Cited by 16 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3