Accuracy and efficiency using frameless transient fiducial registration in stereoelectroencephalography and deep brain stimulation

Author:

Hines Kevin1,Matias Caio M.1,Leibold Adam1,Sharan Ashwini1,Wu Chengyuan1

Affiliation:

1. Department of Neurosurgery, Thomas Jefferson University and Jefferson Hospital for Neuroscience, Philadelphia, Pennsylvania

Abstract

OBJECTIVE Stereotactic surgical methods continue to advance technologically. Frameless transient fiducial registration (FTFR) systems have been developed and avoid the need to move or position a patient in a frame after already receiving registration imaging. One such system, Neurolocate, has recently become available as a robotic attachment for the Neuromate stereotactic robot. This study is the largest in the literature to evaluate the accuracy of frameless registration using Neurolocate versus frame-based registration (FBR) methods in both deep brain stimulation (DBS) and stereoelectroencephalography (SEEG). Additionally, the authors sought to reevaluate factors affecting accuracy in both procedures. METHODS This study was a retrospective chart and imaging review of 88 consecutive procedures (involving 621 electrodes) implanting either DBS or SEEG at the authors’ institution over a 5-year period from March 2015 to March 2020. Registration duration, radial target entry point, and Euclidean target implantation accuracies, as well as factors affecting accuracy, were recorded for each patient. RESULTS SEEG procedures included 38 patients and 525 implanted electrodes (294 using FBR and 231 using FTFR). DBS procedures included 50 patients and 96 implanted electrodes (65 using FBR and 31 using FTFR). Overall, FTFR registration was significantly more accurate (median 0.1 mm, IQR 0–0.4 mm) compared with FBR (median 1.3 mm, IQR 0.9–1.5 mm; p = 0.04). Likewise, FTFR had a significantly shorter duration of registration (median 84 minutes, IQR 77.3–95.3 minutes) when compared with FBR (median 110.5 minutes, IQR 107.3–138 minutes; p = 0.02). No significant differences were found when examining the radial entry point and Euclidean target implantation errors of each method. CONCLUSIONS FTFR with the Neurolocate system represents a technique that may decrease operative time while maintaining the high accuracy previously demonstrated by other stereotactic methods, despite an initial surgeon learning curve. It should be investigated in future studies to continue to improve stereotactic accuracies in neurosurgery.

Publisher

Journal of Neurosurgery Publishing Group (JNSPG)

Subject

Genetics,Animal Science and Zoology

Reference18 articles.

1. The path to surgical robotics in neurosurgery;Khanna O,2021

2. Technique, results, and complications related to robot-assisted stereoelectroencephalography;González-Martínez J,2016

3. Registration accuracy of CT/MRI fusion for localisation of deep brain stimulation electrode position: an imaging study and systematic review;Geevarghese R,2016

4. In vivo measurement of the frame-based application accuracy of the Neuromate neurosurgical robot;von Langsdorff D,2015

5. A new tool for touch-free patient registration for robot-assisted intracranial surgery: application accuracy from a phantom study and a retrospective surgical series;Cardinale F,2017