Analysis of in vivo kinematics of 3 different cervical devices: Bryan disc, ProDisc-C, and Prestige LP disc

Author:

Kowalczyk Izabela12,Lazaro Bruno C. R.3,Fink Marie3,Rabin Doron3,Duggal Neil13

Affiliation:

1. 1Department of Medical Biophysics;

2. 2Centre for Functional and Metabolic Mapping, Robarts Research Institute, University of Western Ontario; and

3. 3Division of Clinical Neurological Sciences: Neurosurgery, University Hospital, London Health Sciences Centre, London, Ontario, Canada

Abstract

Object Cervical arthroplasty has emerged as a means of preventing adjacent segment disease by preserving motion, restoring sagittal balance, and mimicking natural spinal kinematics. The purpose of this retrospective in vivo study was to characterize the impact of arthroplasty on sagittal balance and segmental kinematics of the cervical spine. Methods Sixty patients receiving the Bryan disc, ProDisc-C, or Prestige LP disc were retrospectively analyzed. Only single-level arthroplasty cases were included in this study. Lateral dynamic radiographs of the cervical spine were evaluated using quantitative measurement analysis software to determine the kinematics at the index level both preoperatively and 1 year postoperatively. Collected parameters included range of motion (ROM), disc angles, shell angles, anterior and posterior disc heights (ADHs/PDHs), translation, and center of rotation (COR). Preoperative and postoperative data were compared using the Student t-test, with p < 0.05 indicating significance. Results The Bryan and Prestige LP discs preserved motion, whereas the ProDisc-C increased segmental ROM from extension to flexion. Following surgery, the Bryan disc exhibited significant shell angle kyphosis, while ProDisc-C and Prestige LP retained lordosis. Both ADHs and PDHs decreased following insertion of the Bryan disc. In contrast, the ProDisc-C increased the ADHs and PDHs by 80% and 52%, respectively, and the Prestige LP disc increased the ADHs and PDHs by 20%. Only the ProDisc-C demonstrated significant translation of 0.7 mm. The ProDisc-C shifted the COR x by 0.9 mm anteriorly, while the Prestige LP disc demonstrated a significant superior shift of 2.2 mm in COR y. Conclusions All discs adequately maintained ROM at the surgical level. The greatest difference among the 3 devices was in the disc height and index angle measurements.

Publisher

Journal of Neurosurgery Publishing Group (JNSPG)

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3