Author:
Yan Kai,Shi Zhan,He Da,Liu Bo,Xiao Bin,Wang Qilong,Tian Wei
Abstract
Abstract
Background
Short-term researches have studied the change of the center of rotation (COR) after the Bryan Cervical disc arthroplasty (CDA). But there is a lack of long-term studies focusing on the location of COR and its influence after surgery.
Methods
Clinical and radiographic materials of patients who received CDA were retrospectively reviewed. Written informed consents were obtained. Clinical outcome was accessed by Japanese Orthopaedic Association (JOA), Neck Disability Index (NDI), and Odom’s scale. Radiographic evaluation underwent before surgery, at early (3 months) follow-up and final (minimal 10 years) follow-up. The ROM of the global cervical spine and index level, the functional spine unit (FSU) angle and C2-C7 angle were measured. COR was identified and its coordinates were calculated. The absolute change of COR-x and COR-y were compared in subgroup analysis.
Results
Sixty patients were included, with an average age of 55.9 ± 8.1 years old. The mean duration of follow up was 135.1 ± 16.1 (120–155) months. JOA, NDI and Odom’s scale showed significant improvements at 10 years after surgery. The COR of index level was located in the posterior superior half of the caudal vertebral body. Following the implant of Bryan Disc, the COR shifted forward and downward. During the 10-year follow-up, the location of COR remained stable. ROM at the index level decreased from 10.6 ± 4.0° preoperatively to 9.3 ± 4.0° at the early follow-up (p = 0.03). The ROM at the index level remained unchanged from early follow-up to the final follow-up (9.3 ± 4.0° vs 9.5 ± 5.2°, p = 0.80). In subgroup analysis, larger changes of both COR-x and COR-y were related with decreased ROM.
Conclusions
Our study illustrated that Bryan CDA could achieved favorable clinical and radiographic outcome over a minimal 10-year follow-up. The reduction of the flexion-extension ROM may be correlated with a more deviated postoperative COR. More attention should be paid to preoperative design and intraoperative technique to obtain a more native COR.
Funder
Beijing Jishuitan Hospital Elite Young Scholar Program
National Natural Science Foundation of China
Publisher
Springer Science and Business Media LLC
Subject
Orthopedics and Sports Medicine,Rheumatology