Preliminary experience with self-expanding closed-cell stent placement in small arteries less than 2 mm in diameter for the treatment of intracranial aneurysms

Author:

Chung Joonho1,Suh Sang Hyun2,Hong Chang-Ki1,Joo Jin-Yang1,Lim Yong Cheol3,Shin Yong Sam4,Kim Yong Bae1

Affiliation:

1. Departments of Neurosurgery and

2. Radiology, Gangnam Severance Hospital, Yonsei University, Seoul;

3. Department of Neurosurgery, Ajou University School of Medicine, Suwon; and

4. Department of Neurosurgery, Seoul St. Mary's Hospital, The Catholic University of Korea, Seoul, Republic of Korea

Abstract

OBJECT The purpose of this study was to report the authors' preliminary experience using self-expanding closed-cell stents deployed in small arteries (< 2 mm in diameter) to treat intracranial aneurysms. METHODS A total of 31 patients were studied. All subjects met the following criteria: 1) they received an Enterprise stent for treatment of a wide-necked aneurysm or a dissecting aneurysm or as part of a stent-salvage procedure; and 2) they had an Enterprise stent deployed in a small parent artery (< 2 mm in diameter) that had no atherosclerotic stenosis. Procedure-related complications and follow-up sizes of the parent arteries were evaluated for safety and patency. RESULTS There were 16 ruptured aneurysms and 15 unruptured aneurysms. Three (9.7%) of the 31 patients experienced procedure-related complications, and they all were asymptomatic. Follow-up angiography was performed in 27 patients (87.1%) (at a mean 15.5 months after surgery). Parent arteries with 2 acute angles (n = 4) were occluded in 3 cases (75.0%), and those with no acute angles (n = 13) or 1 acute angle (n = 6) showed 100% patency on follow-up angiography. There was a significant difference between the follow-up sizes (mean 1.72 ± 0.30 mm) of parent arteries and their sizes (mean 1.59 ± 0.26 mm) before treatment (95% CI − 0.254 to − 0.009 mm; p = 0.037, paired-samples t-test). CONCLUSIONS In the current series the deployment of self-expanding closed-cell stents in small arteries was safe and resulted in good patency, especially when the stents were deployed in segments of the parent artery with no acute angles or only 1 acute angle.

Publisher

Journal of Neurosurgery Publishing Group (JNSPG)

Subject

Genetics,Animal Science and Zoology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3