Percutaneous “K-wireless” pedicle screw fixation technique: an evaluation of the initial experience of 100 screws with assessment of accuracy, radiation exposure, and procedure time

Author:

Spitz Steven M.,Sandhu Faheem A.,Voyadzis Jean-Marc

Abstract

OBJECT Percutaneous pedicle screws are used to provide rigid internal fixation in minimally invasive spinal procedures and generally require the use of Kirchner wires (or K-wires) as a guide for screw insertion. K-wires can bend, break, advance, or pull out during the steps of pedicle preparation and screw insertion. This can lead to increased fluoroscopic and surgical times and potentially cause neurological, vascular, or visceral injury. The authors present their experience with a novel “K-wireless” percutaneous pedicle screw system that eliminates the inherent risks of K-wire use. METHODS A total of 100 screws were placed in 28 patients using the K-wireless percutaneous screw system. Postoperative dedicated spinal CT scans were performed in 25 patients to assess the accuracy of screw placement. Screw placement was graded A through D by 2 independent radiologists: A = within pedicle, B = breach < 2 mm, C = breach of 2–4 mm, and D = breach > 4 mm. Screw insertion and fluoroscopy times were also recorded in each case. Clinical complications associated with screw insertion were documented. RESULTS A total of 100 K-wireless percutaneous pedicle screws were placed into the lumbosacral spine in 28 patients. Postoperative CT was performed in 25 patients, thus the placement of only 90 screws was assessed. Eighty-seven screws were placed within the pedicle confines (Grade A), and 3 violated the pedicle (2 Grade B [1 lateral, 1 medial] and 1 Grade D [medial]) for an overall accuracy rate of 96.7%. One patient required reoperation for screw repositioning due to a postoperative L-5 radiculopathy secondary to a Grade D medial breach at L-5. This patient experienced improvement of the radiculopathy after reoperation. Average screw insertion and fluoroscopy times were 6.92 minutes and 22.7 seconds per screw, respectively. CONCLUSIONS The results of this study demonstrate that the placement of K-wireless percutaneous pedicle screws is technically feasible and can be performed accurately and safely with short procedure and fluoroscopy times.

Publisher

Journal of Neurosurgery Publishing Group (JNSPG)

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3