Quadrupolar Ion Excitation for Radiofrequency-Only Mass Filter Operation

Author:

Douglas Don J.1,Polyakov A.2,Konenkov Nikolai V.2

Affiliation:

1. Department of Chemistry, University of British Columbia, 2036 Main Mall, Vancouver, BC, V6T 1Z1, Canada

2. Physical and Mathematical Department, Ryazan State University, Ryazan, Svoboda 46, 390000, Russia

Abstract

Trajectory calculations are used to model a mass filter based on the radiofrequency (rf)-only operation of a linear quadrupole with resonant quadrupole excitation of ions (resonant excitation applied with the same spatial electric field as the main quadrupole rf field). Ions are not trapped, but pass continuously through the quadrupole. Excited ions gain axial kinetic energy in the fringe field at the quadrupole exit, overcome a stopping potential and are transmitted to an external detector. No quadrupole direct current is required, unlike conventional operation at the tip of the first stability diagram. Quadrupole excitation can be applied with amplitude or frequency modulation of the main rf voltage, or with an auxiliary excitation voltage. All three methods give the same mass resolution. The mass resolution, R, is given by R ≈ 0.5 q(dβ/d q) n where q is a Mathieu parameter, β( q), determines the frequency of ion oscillation and n is the number of cycles of the rf field experienced by an ion, determined by the flight time through the quadrupole. A disadvantage of this mode of operation is that the flight times of the ions and the excitation amplitudes or modulation depths need to be synchronized.

Publisher

SAGE Publications

Subject

Spectroscopy,Atomic and Molecular Physics, and Optics,General Medicine

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Dipole and quadrupole resonance excitation in linear quadrupoles;European Journal of Mass Spectrometry;2023-10-11

2. Mass Filter with Phase Modulation of Radio Frequency Voltage;Journal of Mass Spectrometry;2020-08-13

3. Quadrupole mass filter operation with dipole direct current and quadrupole radiofrequency excitation;Rapid Communications in Mass Spectrometry;2018-10-14

4. Linear ion trap mass selectivity with impulse power supply and sinusoidal dipolar excitation;Rapid Communications in Mass Spectrometry;2016-11-06

5. Mass resolution of linear quadrupole ion traps with round rods;Rapid Communications in Mass Spectrometry;2014-09-17

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3