Reliability of a Smartphone Compared With an Inertial Sensor to Measure Shoulder Mobility: Cross-Sectional Study

Author:

Roldán-Jiménez CristinaORCID,Martin-Martin JaimeORCID,Cuesta-Vargas Antonio IORCID

Abstract

Background The shoulder is one of the joints with the greatest mobility within the human body and its evaluation is complex. An assessment can be conducted using questionnaires or functional tests, and goniometry can complement the information obtained in this assessment. However, there are now validated devices that can provide more information on the realization of movement, such as inertial sensors. The cost of these devices is usually high and they are not available to all clinicians, but there are also inertial sensors that are implemented in mobile phones which are cheaper and widely available. Results from the inertial sensors integrated into mobile devices can have the same reliability as those from dedicated sensors. Objective This study aimed to validate the use of the Nexus 4 smartphone as a measuring tool for the mobility of the humerus during shoulder movement compared with a dedicated InertiaCube3 (Intersense) sensor. Methods A total of 43 subjects, 27 affected by shoulder pathologies and 16 asymptomatic, participated in the study. Shoulder flexion, abduction, and scaption were measured using an InertiaCube3 and a Nexus 4 smartphone, which were attached to the participants to record the results simultaneously. The interclass correlation coefficient (ICC) was calculated based on the 3 movements performed. Results The smartphone reliably recorded the velocity values and simultaneously recorded them alongside the inertial sensor. The ICCs of the 3 gestures and for each of the axes of movement were analyzed with a 95% CI. In the abduction movement, the devices demonstrated excellent interclass reliability for the abduction humeral movement axis (Cronbach alpha=.98). The axis of abduction of the humeral showed excellent reliability for the movements of flexion (Cronbach alpha=.93) and scaption (Cronbach alpha=.98). Conclusions Compared with the InertiaCube3, the Nexus 4 smartphone is a reliable and valid tool for recording the velocity produced in the shoulder.

Publisher

JMIR Publications Inc.

Subject

Health Informatics

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3