Evaluation of the Parkinson’s Remote Interactive Monitoring System in a Clinical Setting: Usability Study

Author:

Bridges BronwynORCID,Taylor JakeORCID,Weber John ThomasORCID

Abstract

Background The fastest-growing neurological disorder is Parkinson disease (PD), a progressive neurodegenerative disease that affects 10 million people worldwide. PD is typically treated with levodopa, an oral pill taken to increase dopamine levels, and other dopaminergic agonists. As the disease advances, the efficacy of the drug diminishes, necessitating adjustments in treatment dosage according to the patient’s symptoms and disease progression. Therefore, remote monitoring systems that can provide more detailed and accurate information on a patient’s condition regularly are a valuable tool for clinicians and patients to manage their medication. The Parkinson’s Remote Interactive Monitoring System (PRIMS), developed by PragmaClin Research Inc, was designed on the premise that it will be an easy-to-use digital system that can accurately capture motor and nonmotor symptoms of PD remotely. Objective We performed a usability evaluation in a simulated clinical environment to assess the ease of use of the PRIMS and determine whether the product offers suitable functionality for users in a clinical setting. Methods Participants were recruited from a user sign-up web-based database owned by PragmaClin Research Inc. A total of 11 participants were included in the study based on the following criteria: (1) being diagnosed with PD and (2) not being diagnosed with dementia or any other comorbidities that would make it difficult to complete the PRIMS assessment safely and independently. Patient users completed a questionnaire that is based on the Movement Disorder Society–sponsored revision of the Unified Parkinson’s Disease Rating Scale. Interviews and field notes were analyzed for underlying themes and topics. Results In total, 11 people with PD participated in the study (female individuals: n=5, 45%; male individuals: n=6, 55%; age: mean 66.7, SD 7.77 years). Thematic analysis of the observer’s notes revealed 6 central usability issues associated with the PRIMS. These were the following: (1) the automated voice prompts are confusing, (2) the small camera is problematic, (3) the motor test exhibits excessive sensitivity to the participant’s orientation and position in relation to the cameras, (4) the system poses mobility challenges, (5) navigating the system is difficult, and (6) the motor test exhibits inconsistencies and technical issues. Thematic analysis of qualitative interview responses revealed four central themes associated with participants’ perspectives and opinions on the PRIMS, which were (1) admiration of purpose, (2) excessive system sensitivity, (3) video instructions preferred, and (4) written instructions disliked. The average system usability score was calculated to be 69.2 (SD 4.92), which failed to meet the acceptable system usability score of 70. Conclusions Although multiple areas of improvement were identified, most of the participants showed an affinity for the overarching objective of the PRIMS. This feedback is being used to upgrade the current PRIMS so that it aligns more with patients’ needs.

Publisher

JMIR Publications Inc.

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3