Abstract
Objective: This research was carried out from September to March 2023 at the National Medical College and Teaching Hospital with the objective to detect most prominent nosocomial infection causing microorganisms in hospital environment.
Methods: A total of 148 environment samples (66 in air samples and 82 surface samples) from different wards were taken from the hospital environment. All the samples were processed following standard microbiological methods.
Results: Gram-positive cocci were the most prominent ones followed by Gram-positive bacilli and then Gram-negative bacilli. Among Gram-positive isolates, coagulase-negative staphylococci accounted for 28.84% of the isolates followed by Staphylococcus aureus with 25.76%, Streptococci with 8.23%, and Gram-positive rods with 17.68%. Among Gram-negative isolates, Acinetobacter spp. accounted for 8.08% followed by Escherichia coli with 1.43% and Klebsiella spp with 0.35%. Among fungal isolates, yeasts were found in higher number with 9.59% in comparison to Aspergillus spp. All Gram-positive isolates were sensitive to vancomycin. Among Gram-negative isolates, E. coli showed the highest susceptibility to amikacin with 85%, Klebsiella spp, and Acinetobacter spp showed the higher degree of susceptibility to ciprofloxacin with 80% and 74.2% respectively.
Conclusions: The high incidence of similar types of bacterial isolates detection in the hospital environment suggests that the environment surrounding the hospital may be significantly contaminated with nosocomial pathogens and could represent a major mode of transmission to patients.
Publisher
Innovare Academic Sciences Pvt Ltd
Reference36 articles.
1. Park DU, Yeom JK, Lee WJ, Lee KM. Assessment of the levels of airborne bacteria, gram-negative bacteria, and fungi in hospital lobbies. Int J Environ Res Public Health 2013;10:541-55.
2. Ponce-Caballero C, Gamboa-Marrufo M, Lopez-Pacheco M, Ceron-Palma I, Quintal-Franco C, Giacoman-Vallejos G, et al. Seasonal variation of airborne fungal propagules indoor and outdoor of domestic environments in Merida, Mexico. Atmosfera 2013;26:369-77.
3. Bozic J, Ilic P, Ilic S. Indoor air quality in the hospital: The influence of heating, ventilating and conditioning systems. Braz Arch Biol Technol 2019;62: ???.
4. Bhattacharyya S, Sarfraz A, Jaiswal N. Hospital indoor air microbial quality: Importance and monitoring Ann Ig 2015;6:154-6.
5. Manorat N, Sinthununsakul N. Indoor air quality and microbial indoor air quality in tertiary care hospital. J Prev Med Assoc Thailand 2019;9:232-41.
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献