Investigating Microbial Contamination of Indoor Air, Environmental Surfaces, and Medical Equipment in a Southwestern Ethiopia Hospital

Author:

Belay Mekdes Mekonen1,Ambelu Argaw2,Mekonen Seblework2,Karbana Gedeno3ORCID,Yemane Bethlehem4

Affiliation:

1. Department of Public Health, College of Medicine and Health Science, Werabe University, Werabe, Ethiopia

2. Water and Health Division, Ethiopian Institute of Water Resources, Addis Ababa University, Addis Ababa, Ethiopia

3. Department of Environmental Health, Institute of Health, Bule Hora University, Bule Hora, Ethiopia

4. Department of Environmental Health, College of Medicine and Health Science, Hawassa University, Hawassa, Ethiopia

Abstract

Introduction: Healthcare-associated infections, primarily caused by microorganisms, are widespread in healthcare facilities. These infections pose a significant challenge, especially in low and middle-income countries, and have a detrimental impact on patient outcomes. It is crucial to assess the level of microbial load and associated factors to prevent the spread of these infections. The objective of this study was to assess the microbial load and identify the factors associated with it in various wards at Jimma Medical Center. Method: A cross-sectional study conducted at Jimma Medical Center. Indoor air samples were collected using the settle plate method with a 1/1/1 scheme. Inanimate surfaces and medical equipment were sampled using Swabs from a 10 × 10 cm area. A total of 268 samples were collected from 10 rooms. Pertinent information regarding the associated factors was gathered using an observational checklist. A multiple linear regression model was used to identify any associations with the microbial load. Result: Out of the total samples, 181 (67.5%) tested positive for culture, and 270 microbes were isolated. The average load of bacteria and fungi in the indoor air ranged from 124.4 to 1607 and 96 to 814.6 Colony-forming unit (CFU)/m3, respectively. The mean total aerobic colony counts of bacteria and fungi from all surfaces in the wards ranged from 5.25 to 43.3 CFU/cm2. Crowdedness [β = 2.748 (95% Confidence Interval (CI): 1.057-4.44)], the presence of waste material [β = 1.747 (95% CI: 0.213-3.282)], and an unclean room [β = 2.505 (95% CI: 0.990-4.019)] were significantly associated with the microbial load. Conclusion: The microbial load detected in indoor air, inanimate surfaces and medical equipment was posing potential health risks. Consequently, it is recommended to implement regular microbial surveillance of the hospital environment and enhance the infection prevention program to mitigate these concerns.

Publisher

SAGE Publications

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3