Evaluation of Activated Partial Thromboplastin Time Mixing Studies Using Several Methods

Author:

Liu Chaonan1,Ling Liqin1,Huang Xunbei1,Mi Jian12,Liao Juan1,Jia Jin1,Wang Xia1,Zhou Jing1

Affiliation:

1. From the Department of Laboratory Medicine, West China Hospital, Sichuan University, Chengdu, Sichuan, China (Liu, Ling, Huang, Mi, Liao, Jia, Wang, Zhou)

2. the Department of Clinical Laboratory, Central Hospital of Panzhihua City, Panzhihua, Sichuan, China (Mi)

Abstract

Context.— A prolonged activated partial thromboplastin time (APTT), a vital screening test for coagulation, can be due to deficiencies in coagulation factors and the existence of factor inhibitors or antiphospholipid antibodies. APTT mixing studies are being optimized to help find the cause. Objective.— To optimize APTT mixing studies, we evaluated existing standards and explored when and how to combine 1:1 and 4:1 mixing. Design.— Patients with a prolonged APTT but otherwise normal prothrombin time and thrombin time were enrolled in our hospital from January 1, 2018, to December 31, 2019. All samples were subjected to 1:1 mixing studies, while 134 were subjected to 4:1. Results.— A total of 251 samples were involved, including 116 with factor deficiencies, 75 with FVIII inhibitors, and 60 with antiphospholipid antibodies. A Rosner index less than 11% or an extended incubation time of more than 3 seconds was better than other existing standards in differentiating factor deficiencies from inhibitors and in differentiating time-dependent inhibitors from time-independent inhibitors, but the approach presented here improves upon those. For the best diagnostic accuracy, samples with a Rosner index between 5.0% and 9.1% need a 4:1 mixing study, while others need 1:1. A combination of Rosner index and percent-extended incubation time-P seemed to offer objective and effective criteria for interpreting the results. Conclusions.— APTT mixing studies had overall good sensitivity and specificity in differentiating factor deficiencies from inhibitors, or time-dependent from time-independent inhibitors. The combination of 1:1 and 4:1 mixing studies can improve the diagnostic ability compared with 1:1 alone.

Publisher

Archives of Pathology and Laboratory Medicine

Subject

Medical Laboratory Technology,General Medicine,Pathology and Forensic Medicine

Cited by 8 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3