Improved Performance in Measurement of Serum Cystatin C by Laboratories Participating in the College of American Pathologists 2019 CYS Survey

Author:

Karger Amy B.1,Long Thomas2,Inker Lesley A.3,Eckfeldt John H.1,

Affiliation:

1. From the Department of Laboratory Medicine & Pathology, University of Minnesota, Minneapolis (Karger, Eckfeldt).

2. From the Department of Biostatistics, College of American Pathologists, Northfield, Illinois (Long).

3. From William B. Schwartz Division of Nephrology, Tufts Medical Center, Department of Medicine, Tufts University School of Medicine, Boston, Massachusetts (Inker).

Abstract

Context.— Use of cystatin C for glomerular filtration rate estimation (eGFR) has garnered heightened interest as a means to avoid race-based medicine, since eGFRcys equations do not require specification of race. Before considering more widespread use of cystatin C, it is important to confirm that assays provide accurate measurements of cystatin C concentration, to ensure accurate GFR estimates. Objective.— To determine if the accuracy of cystatin C measurements in laboratories participating in the College of American Pathologists (CAP) Cystatin C (CYS) survey has improved since 2014. Design.— Two fresh frozen serum pools, the first from healthy donors without chronic kidney disease (CKD), and the second from patients with CKD, along with a synthetically prepared elevated cystatin C pool, were sent to laboratories participating in the 2019 CYS-A survey. Target values were established by using 2 immunoassays and a bracketed 2-point calibration with diluted ERM-DA471/IFCC reference material. Results.— For the healthy donor fresh frozen pool (ERM-DA471/IFCC-traceable target of 0.725 mg/L), the all-method mean (standard deviation, coefficient of variation) was 0.731 mg/L (0.071, 9.7%). For the CKD pool (ERM-DA471/IFCC-traceable target of 2.136 mg/L), the all-method mean was 2.155 mg/L (0.182, 8.4%). For the synthetically spiked pool (ERM-DA471/IFCC-traceable target of 1.843 mg/L), the all-method mean was 1.886 mg/L (0.152, 8.1%). This represents marked improvement in accuracy and between-method agreement compared to the 2014 CAP survey. Conclusions.— Manufacturers have markedly improved accuracy and between-method agreement of cystatin C measurement procedures since 2014, which allows for greater confidence in estimated GFR relying on cystatin C.

Publisher

Archives of Pathology and Laboratory Medicine

Subject

Medical Laboratory Technology,General Medicine,Pathology and Forensic Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3