AbstractThe Occupational Safety and Health Administration (OSHA) revised the Bloodborne Pathogen Standard and, on July 17, 2001, began enforcing the use of appropriate and effective sharps devices with engineered sharps-injury protection. OSHA requires employers to maintain a sharps-injury log that records, among other items, the type and brand of contaminated sharps device involved in each injury. Federal OSHA does not require needlestick injury rates to be calculated by brand or type of device. A sufficient sample size to show a valid comparison of safety devices, based on injury rates, is rarely feasible in a single facility outside of a formal research trial. Thus, calculations of injury rates should not be used by employers for product evaluations to compare the effectiveness of safety devices. This article provides examples of sample-size requirements for statistically valid comparisons, ranging from 100,000 to 4.5 million of each device, depending on study design, and expected reductions in needlestick injury rates.

Publisher

Cambridge University Press (CUP)

Subject

Infectious Diseases,Microbiology (medical),Epidemiology

Reference9 articles.

1. Device-Specific Risk of Needlestick Injury in Italian Health Care Workers

2. Occupational exposure to bloodborne pathogens. Final Rule (29 CFR 1910.1030);Federal Register,2001

3. Prevention of needlestick injuries in healthcare workers: 27 month experience with a resheathable ‘safety’ winged steel needle using CDC NASH Database;Chen;Infect Control Hosp Epidemiol,2000

4. Evaluation of a safety IV catheter (Insyte Autoguard, Becton-Dickinson) using the Centers for Disease Control and Prevention (CDC) National Surveillance System for Hospital Healthcare Workers database;Mendelson;Infect Control Hosp Epidemiol,2000

5. Injuries from vascular access devices: high risk and preventable. Collaborative EPINet Surveillance Group;Jagger;J Intraven Nurs,1997

Cited by 21 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3