Cuffless blood pressure estimation based on haemodynamic principles: progress towards mobile healthcare

Author:

Yamakoshi Takehiro12,Rolfe Peter34,Yamakoshi Ken-ichi567

Affiliation:

1. Institute of Liberal Arts and Science, Kanazawa University, Kanazawa, Ishikawa, Japan

2. Division of Research & Development, MedicAlpha Corporation, Kobe, Hyogo, Japan

3. Department of Automatic Measurement and Control, Harbin Institute of Technology, Nangang, Harbin, China

4. Oxford BioHorizons Ltd., Maidstone, United Kingdom

5. College of Science and Engineering, Kanazawa University, Kanazawa, Ishikawa, Japan

6. Department of Orthopaedic Surgery, Showa University, Tokyo, Japan

7. Division of Research and Development, Research Institute of Life Benefit, Nonprofit Organization (NPO), Sapporo, Hokkaido, Japan

Abstract

Background Although cuff-sphygmomanometry is used worldwide in medical and healthcare fields, it is a fact that the use of an occlusive cuff to obtain blood pressure (BP) is troublesome and inconvenient. There have therefore been on-going efforts to devise methods that do not require the use of a cuff, almost all being based on the measurement of pulse wave velocity or pulse transit time, but so far few significant developments have been made, especially regarding measurement accuracy. We have previously reported a smartphone-based cuffless method using a linear multiple regression calibration model comprising of BP obtained with a cuff-sphygmomanometer as an objective variable and modified normalized pulse volume (mNPV: a measure of vasoconstrictive activity in a finger) and pulse rate (PR) as explanatory variables. This requires a number of subjects to construct a calibration model and thus is largely dependent on the accuracy due to the model. To address these drawbacks, we report here a new cuffless method to surpass considerably the results of our previous study as well as earlier works. Methods With this method we can estimate BP, with much higher accuracy, using mNPV and PR, both also obtained from a smartphone-derived photoplethysmogram. The subject firstly performs a cuff-based BP measurement in parallel with the acquisition of mNPV and PR from a smartphone. These parameters are set as initial values (BPc0, mNPV0 and PR0; initial calibration procedure). Then, the estimated BP (BPe) can be calculated from the relation: “BPe = (BPc0·PR·mNPV)/(PR0·mNPV0)”, which is derived from the so-called haemodynamic Ohm’s law. To validate this method, preliminary experiments using 13 volunteers were carried out to compare results from the new method with those from the cuff-sphygmomanometry, used as a reference. Results Altogether 299 paired data sets were analyzed: A good agreement was found between the cuff-based and the estimated BP values, with correlation coefficients of 0.968 for systolic BP (SBP), 0.934 for mean BP (MBP) and 0.844 for diastolic BP (DBP). Bland-Altman analyses for the BPe (SBPe, MBPe, DBPe) and the BPc (SBPc, MBPc, DBPc) values also supported these comparison results. Mean absolute differences between the BPe and the BPc values in total subjects were less than 5 mmHg. Fairly good tracking availability in terms of time series data of the BPc against the corresponding BPe values was also confirmed in each subject during the study periods (1–2 weeks for 12 subjects and about 4 months for one subject). Discussion The present study reported the successful development of the new cuffless BP estimation method, given as the status of a trial stage of investigation. This method could easily be used with various smartphones, smart watches, and finger-based devices, and it appears to have significant potential as a convenient substitute for conventional cuff-sphygmomanometers as well as for practical application to mobile healthcare.

Funder

Grant-in-Aid for Scientific Research

Japan Society for the Promotion of Science

Publisher

PeerJ

Subject

General Agricultural and Biological Sciences,General Biochemistry, Genetics and Molecular Biology,General Medicine,General Neuroscience

Cited by 10 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3