Abstract

Background Neck pain, one of the most common musculoskeletal diseases, affects 222 million people worldwide. The cervical range of motion (CROM) is a tool used to assess the neck’s state across three movement axes: flexo-extension, rotation, and lateral flexion. People with neck pain often have a reduced CROM, and they feel pain at the end-range and/or accompany neck movements with compensatory trunk movements. Virtual reality (VR) setups can track the movement of the head and other body parts in order to create the sensation of immersion in the virtual environment. Using this tracking position information, a CROM assessment can be performed using a VR setup that may be carried out autonomously from the user’s home. The objectives of this study were to develop a VR experience that could be used to perform a CROM assessment, and to evaluate the intra-rater and inter-rater reliability of the CROM measures guided by this VR experience. To the best of our knowledge, a study of this type has not been carried out before. Materials & Methods A total of 30 asymptomatic adults were assessed using a VR device (HTC Vive Pro Eye™). Two raters provided support with the VR setup, and the participants were guided by the VR experience as they performed the movements. Each rater tested each subject twice, in random order. In addition to a head-mounted display (HMD), a tracker located on the subject’s back was used to measure trunk compensatory movements. The CROM was estimated using only the HMD position and this measurement was corrected using the tracker data. The mean and standard deviation were calculated to characterize the CROM. To evaluate the reliability, the interclass correlation coefficients (ICC) were calculated for intra-rater and inter-rater analysis. The standard error of measurement and minimum detectable change were also calculated. The usability of the VR system was measured using the Spanish version of the System Usability Scale. Results The mean CROM values in each axis of movement were compatible with those described in the literature. ICC values ranged between 0.86 and 0.96 in the intra-rater analysis and between 0.83 and 0.97 in the inter-rater analysis; these values were between good and excellent. When applying the correction of the trunk movements, both the intra-rater and inter-rater ICC values slightly worsened except in the case of the lateral flexion movement, where they slightly improved. The usability score of the CROM assessment/VR system was 86 points, which is an excellent usability score. Conclusion The reliability of the measurements and the usability of the system indicate that a VR setup can be used to assess CROM. The reliability of the VR setup can be affected by slippage of the HMD or tracker. Both slippage errors are additive, i.e., only when the sum of these two errors is less than the compensatory movement do the measurements improve when considering the tracker data.

Funder

Ministry of Science, Innovation, and Universities of Spain

European Regional Development Fund of the European Commission

Publisher

PeerJ

Subject

General Agricultural and Biological Sciences,General Biochemistry, Genetics and Molecular Biology,General Medicine,General Neuroscience

Reference66 articles.

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3