Ex vivo evaluation of a new neonatal/infant oxygenator: comparison of the Terumo CAPIOX® Baby RX with Dideco Lilliput 1 and Polystan Safe Micro in the piglet model

Author:

Dubois J1,Jamaer L1,Mees U2,Pauwels J-L2,Briers F2,Lehaen J2,Hendrikx M3

Affiliation:

1. Department of Cardiac Anaesthesia, Virga Jesse Hospital, B-3500 Hasselt, Belgium

2. Department of Cardiothoracic Surgery, Virga Jesse Hospital, B-3500 Hasselt, Belgium

3. Department of Cardiothoracic Surgery, Virga Jesse Hospital, B-3500 Hasselt, Belgium, Faculty of Medicine, Biomed Limburgs Universitair Centrum, Universitaire Campus, B-3590 Diepenbeek, Belgium,

Abstract

Objective: A newly developed neonatal and infant oxygenator with a nonheparin biocompatible polymer coating, low priming volume (43 mL), high oxygen transfer, wide operating range (<1.5 L/min) and low pressure drop represents a promising solution for cardiac surgery in neonates and infants. We compared the new CAPIOX® Baby RX, Terumo (BRX) with two commonly used neonatal oxygenators: Dideco Lilliput 1 (DL1) and Polystan Safe Micro (PSM) in a piglet model. Methods: Fifteen piglets (5.6±1.3 kg) were placed on standardized cardiopulmonary bypass (CPB) for 6 hours using one of the three oxygenators ( n = 5 in each group). After 120 min, the system was cooled to 25°C for 60 min and then returned to normothermia. Arterial and venous blood gas data and temperature were recorded continuously by a CDI500 System (Terumo). Pressure drop, FiO2 and gas flow were recorded. Blood samples were taken before CBP, after 10 min, before and after cooling, and at the end. Total blood counts, thrombin-antithrombin complex and plasma-free haemoglobin (PfHb) were measured. Results: All oxygenators showed acceptable performance for the duration of CPB. The BRX had lower mean gas flow (0.33±0.05 L/min) and FiO2 (0.43± 0.02%) throughout CPB than the DL1 (1.14±0.25 L/min, p = 0.006 and 0.60±0.02%, p = 0.009, respectively) or the PSM (1.47±0.87 L/min and 0.54±0.08%, p = ns). Pressure drop in the BRX group ranged from 12 to 22 mmHg. This was significantly lower than in the DL1 group (39-65 mmHg, p = 0.005). In the PSM group, values ranged between 24 and 33 mmHg (p = ns). The increase in PfHb at six hours was significantly lower in the BRX (11.3±4.2 ng/dL) versus the DL1 (42.2±6.1 ng/dL, p = 0.004) and the PSM (56.7±15.5 ng/dL, p = 0.045). Conclusions: The BRX is as safe as the DL1 and the PSM, with superior performance in pressure drop, efficient blood gas management and lower haemolysis. The BRX exhibited the lowest prime, hold-up volume and breakthrough time.

Publisher

SAGE Publications

Subject

Advanced and Specialized Nursing,Cardiology and Cardiovascular Medicine,Safety Research,Radiology, Nuclear Medicine and imaging,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3