EXPERIMENTAL AND NUMERICAL STUDY ON EFFECTS OF NEW-GENERATION FINNED HEAT EXCHANGER ON THERMAL PERFORMANCE OF THERMOELECTRIC COOLING SYSTEMS
-
Published:2024
Issue:5
Volume:55
Page:41-57
-
ISSN:1064-2285
-
Container-title:Heat Transfer Research
-
language:en
-
Short-container-title:Heat Trans Res
Author:
Muratçobanoğlu Burak,Mandev Emre,Ömeroğlu Gökhan,Akpınar Fatih,Öz Erkan,Afshari Faraz
Abstract
In this study, an attempt has been made to increase the efficiency of the thermoelectric refrigerator by designinig a new-generation finned heat exchanger. Surface extension, which is one of the most applied passive heat transfer enhancement techniques, was applied for this finned heat exchanger. In this application, the heat absorbed from the cooling room is transferred to the external environment more effectively. In addition, by using an external thermoelectric element (which is installed with the secondary heat exchanger), the heat exchanger cools down faster and the heat is transferred
to the environment more quickly. The manufactured cooling system was tested experimentally under different working
conditions, including natural and forced convection. The effects of air velocity and applied voltage to the external TE module on thermal performance were examined. Additionally, the external finned heat exchanger has been simulated and heat transfer characteristics have been evaluated using computational fluid dynamics. The lowest and highest
COP values have been obtained as 0.003 and 0.011, respectively, when the external TE module has been passive.
By providing 12 V for the external TE module, the lowest and highest COP values have been observed as 0.0031
and 0.0042, respectively. In addition, the importance of surface extension applications for the efficient operation of thermoelectric elements has been emphasized.
Subject
Fluid Flow and Transfer Processes,Mechanical Engineering,Condensed Matter Physics
Reference47 articles.
1. Abderezzak, B., Dreepaul, R.K., Busawon, K., and Chabane, D., Experimental Characterization of a Novel Configuration of Thermoelectric Refrigerator with Integrated Finned Heat Pipes, Int. J. Refrig., vol. 131, pp. 157-167, 2021. 2. Abdul-Wahab, S.A., Elkamel, A., Al-Damkhi, A.M., Is' Haq, A., Al-Rubai'ey, H.S., Al-Battashi, A.K., Al-Tamimi, A.R., Al-Mamari, H., and Chutani, M.U., Design and Experimental Investigation of Portable Solar Thermoelectric Refrigerator, Renew. Energy, vol. 34, no. 1, pp. 30-34, 2009. 3. Abramzon, B., Numerical Optimization of the Thermoelectric Cooling Devices, ASME J. Electron. Packag., vol. 129, no. 3, pp. 339-347, 2006. 4. Afshari, F., Ceviz, M.A., Manay, E., Ceylan, M., and Muratçobanoglu, B., Performance Analysis of Air-to-Water Binary Thermoelectric Peltier Cooling Systems and Determination of Optimum Arrangement, J. Braz. Soc. Mech. Sci. Eng., vol. 44, no. 9, Article ID 424, 2022a. 5. Afshari, F., Ceviz, M.A., Mandev, E., and Yildiz, F., Effect of Heat Exchanger Base Thickness and Cooling Fan on Cooling Performance of Air-to-Air Thermoelectric Refrigerator; Experimental and Numerical Study, Sustain. Energy Technol. Assess., vol. 52, Article ID 102178, 2022b.
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
|
|