Hermeticity and Reliability of Au-Au Thermocompression Bonds, Realized at Low Temperature
-
Published:2014-08-14
Issue:5
Volume:64
Page:167-176
-
ISSN:1938-5862
-
Container-title:ECS Transactions
-
language:
-
Short-container-title:ECS Trans.
Author:
Malik Nisant,Tofteberg Hannah,Poppe Erik,Finstad Terje G,Schjolberg-Henriksen Kari
Abstract
Hermeticity and reliability of four laminates bonded at different temperatures by Au-Au thermocompression bonding have been investigated. Laminates of diameter 150 mm were realized by bonding a wafer containing membrane structures to Si wafers with patterned bond frames. The laminates were bonded applying a bonding pressure of 8.5 MPa at temperatures of 150–300 °C for 15 minutes. The hermetic properties were estimated by measurement of membrane deflection at two different times after bonding. Reliability was tested by exposing the laminates to a steady-state life test, a thermal shock test, and a moisture resistance test. A dicing yield above 90 % was obtained for laminates bonded at or above 150 °C. Laminates bonded at 200 °C and above had significantly higher hermetic yield than the laminate bonded at 150 °C. No degradation in hermeticity was observed after the reliability tests. A maximum leak rate in the range of 10-11 mbar×l×s-1 was estimated.
Publisher
The Electrochemical Society
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献