Author:
Shayegh Seyed S,Hakimaneh Seyed MR,Baghani Mohammad T,Shidfar Shireen,Kashi Farinaz K,Zamanian Amirhosein,Arezoobakhsh Ali
Abstract
ABSTRACT
Aim
The purpose of this in vitro study was to investigate the effect of interimplant distance and cyclic loading on the retention of two locator attachment systems.
Materials and methods
A total of 72 acrylic resin blocks were fabricated and divided into six groups of six pairs each. Locators of DIO and 3i implant systems were positioned on analogs in three different interimplant distances (19, 23, and 29 mm). The blocks were attached to a universal testing machine, and 1,440 dislodging cycles by the force of 136 N were applied. After 0, 120, 360, 720, and 1,440 cycles, the retention was recorded. Three-way analysis of variance (ANOVA) was used to test for differences in retention between the various combinations of the locator, interimplant distance, and cyclic loadings.
Results
Interimplant distance was significantly associated with retention, independent of the locator system used, and dislodgement force cycles. Mean retention was significantly higher under the 3i system relative to the DIO system (p < 0.0001). This association varied with both interimplant distance (p > 0.0001) and dislodgement force (p < 0.0001) as well as across the various combinations of distance and cycle (p < 0.0001).
Conclusion
Interimplant distances could affect the initial retention of locator attachments. There was little difference in retention between distances of 23 and 29 mm across all cycles when both locator systems were combined. Distance of 23mm was associated with superior retention in the DIO system. With regard to the speed of retention decrease, the 23 mm distance was associated with better performance.
Clinical significance
Interimplant distance could play a significant role in overdenture retention with locator attachments.
How to cite this article
Shayegh SS, Hakimaneh SMR, Baghani MT, Shidfar S, Kashi FK, Zamanian A, Arezoobakhsh A. Effect of Interimplant Distance and Cyclic Loading on the Retention of Overdenture Attachments. J Contemp Dent Pract 2017;18(11):1078-1084.
Publisher
Jaypee Brothers Medical Publishing
Cited by
4 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献