Effect of Three Different Contamination Removal Methods on Bond Strength of a Self-etching Adhesive to Dentin Contaminated with an Aluminum Chloride Hemostatic Agent

Author:

Oskoee Siavash Savadi,Bahari Mahmoud,Ajami Amir Ahmad,Kahnamoii Mehdi Abed,Kimyai Soodabeh,Pournaghi-Azar Fatemeh

Abstract

ABSTRACT Aim This study evaluated the effect of three different contamination removal methods on bond strength of one-step self-etching adhesive to dentin contaminated with an aluminum chloride hemostatic agent. Materials and methods One hundred noncarious adult molars were used in this study; 2-mm-thick dentin disks were prepared and randomly assigned to 5 groups (n = 20). Group I: control; group II: hemostatic agent-contaminated; group III: hemostatic agent-contaminated and rinsing with water; group IV: hemostatic agent-contaminated and ethylene diamine tetraacetic acid (EDTA) application; and group V: hemostatic agent-contaminated and phosphoric acid application. Clearfil S3 Bond was used to bond composite to dentin surfaces. Subsequent to adding composite cylinders the shear bond strength test was performed. Data were analyzed by one-way ANOVA and Tukey test. Two additional specimens from each group were prepared and evaluated under scanning electron microscope (SEM). Results There were statistically significant differences in bond strength among the groups (p < 0.001). In two-by-two comparisons statistically significant differences were observed in bond strength values between all the groups (p < 0.001) except for groups I and IV (p = 0.933). Conclusion Aluminum chloride hemostatic agent adversely affected the bond strength of self-etch adhesive to dentin. However, application of EDTA increased the bond strength to the level of normal dentin. Clinical significance EDTA and phosphoric acid removed aluminum chloride hemostatic agent contamination of dentin surfaces. However, unlike EDTA phosphoric acid failed to increase the bond strength of self-etch adhesive to dentin to the level of the control group. How to cite this article Ajami AA, Kahnamoii MA, Kimyai S, Oskoee SS, Pournaghi-Azar F, Bahari M, Firouzmandi M. Effect of Three Different Contamination Removal Methods on Bond Strength of a Self-etching Adhesive to Dentin Contaminated with an Aluminum Chloride Hemostatic Agent. J Contemp Dent Pract 2013;14(1):26-33.

Publisher

Jaypee Brothers Medical Publishing

Subject

General Dentistry

Reference86 articles.

1. Abdalla AI, Davidson CL. Bonding efficiency and interfacial morphology of one-bottle adhesives to contaminated dentin surfaces. Am J Dent 1998;11:281-85.

2. Kaneshima T, Yatani H, Kasai T, Watanabe EK, Yamashita A. The influence of blood contamination on bond strengths between dentin and an adhesive resin cement. Oper Dent 2000;25:195-201.

3. In vitro bond strength of two adhesives to enamel and dentin under normal and contaminated conditions

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3