Author:
Oskoee Siavash Savadi,Bahari Mahmoud,Ajami Amir Ahmad,Kahnamoii Mehdi Abed,Kimyai Soodabeh,Pournaghi-Azar Fatemeh
Abstract
ABSTRACT
Aim
This study evaluated the effect of three different contamination removal methods on bond strength of one-step self-etching adhesive to dentin contaminated with an aluminum chloride hemostatic agent.
Materials and methods
One hundred noncarious adult molars were used in this study; 2-mm-thick dentin disks were prepared and randomly assigned to 5 groups (n = 20). Group I: control; group II: hemostatic agent-contaminated; group III: hemostatic agent-contaminated and rinsing with water; group IV: hemostatic agent-contaminated and ethylene diamine tetraacetic acid (EDTA) application; and group V: hemostatic agent-contaminated and phosphoric acid application. Clearfil S3 Bond was used to bond composite to dentin surfaces. Subsequent to adding composite cylinders the shear bond strength test was performed. Data were analyzed by one-way ANOVA and Tukey test. Two additional specimens from each group were prepared and evaluated under scanning electron microscope (SEM).
Results
There were statistically significant differences in bond strength among the groups (p < 0.001). In two-by-two comparisons statistically significant differences were observed in bond strength values between all the groups (p < 0.001) except for groups I and IV (p = 0.933).
Conclusion
Aluminum chloride hemostatic agent adversely affected the bond strength of self-etch adhesive to dentin. However, application of EDTA increased the bond strength to the level of normal dentin.
Clinical significance
EDTA and phosphoric acid removed aluminum chloride hemostatic agent contamination of dentin surfaces. However, unlike EDTA phosphoric acid failed to increase the bond strength of self-etch adhesive to dentin to the level of the control group.
How to cite this article
Ajami AA, Kahnamoii MA, Kimyai S, Oskoee SS, Pournaghi-Azar F, Bahari M, Firouzmandi M. Effect of Three Different Contamination Removal Methods on Bond Strength of a Self-etching Adhesive to Dentin Contaminated with an Aluminum Chloride Hemostatic Agent. J Contemp Dent Pract 2013;14(1):26-33.
Publisher
Jaypee Brothers Medical Publishing
Reference86 articles.
1. Abdalla AI, Davidson CL. Bonding efficiency and interfacial morphology of one-bottle adhesives to contaminated dentin surfaces. Am J Dent 1998;11:281-85.
2. Kaneshima T, Yatani H, Kasai T, Watanabe EK, Yamashita A. The influence of blood contamination on bond strengths between dentin and an adhesive resin cement. Oper Dent 2000;25:195-201.
3. In vitro bond strength of two adhesives to enamel and dentin under normal and contaminated conditions
Cited by
13 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献