Bonding Protocols to Reverse the Bond Strength of a Universal Adhesive to Hemostatic Agent-contaminated Dentin

Author:

Pratabsingha J1,Noppawong S2,Thamsoonthorn C3,Vichathai W4,Saikaew P5

Affiliation:

1. Jaikaew Pratabsingha, DDS, Institute of Dentistry, Department of Medical Services, Nonthaburi, Thailand

2. Sawaphon Noppawong, DDS, Institute of Dentistry, Department of Medical Services, Nonthaburi, Thailand

3. Chanida Thamsoonthorn, DDS, MSD, Grad Dip in Clin Sc, Institute of Dentistry, Department of Medical Services, Nonthaburi, Thailand

4. Weeranun Vichathai, DDS, Grad Dip in Clin Sc, Dip Thai Board of General Dentistry, Institute of Dentistry, Department of Medical Services, Nonthaburi, Thailand

5. *Pipop Saikaew, DDS, MSc, PhD, assistant professor, Department of Operative Dentistry and Endodontics, Faculty of Dentistry, Mahidol University, Bangkok, Thailand

Abstract

SUMMARY Objective: To evaluate the effect of different bonding protocols on the microtensile bond strength (μTBS) of a universal adhesive to dentin contaminated with a hemostatic agent. Methods and Materials: Ninety-five extracted premolars were used in this study. For the μTBS test, 80 teeth were cut to expose mid-coronal dentin and randomly divided into two groups (uncontaminated dentin and hemostatic agent-contaminated dentin). Each group was further divided into five subgroups (n=8/group): 1) SE: no additional treatment, 2) ER: etching with 32% phosphoric acid, 3) CHX: rinsing with 0.2% chlorhexidine, 4) EDTA: rinsing with 17% EDTA, and 5) T40: application of universal adhesive for 40 seconds. A universal adhesive was applied followed by resin composite build-up. μTBS test was performed after 24 hours of water storage. Two-way analysis of variance (ANOVA) was calculated followed by the Duncan testing (α=0.05). The failure mode was analyzed using light microscopy. Additional teeth were prepared for energy-dispersive X-ray (EDX) analysis (n=1/group) and resin-dentin interface observation (n=2/group) using scanning electron microscopy. Results: Adverse effects of hemostatic agent contamination on the bonding performance of a universal adhesive was found in the SE, CHX, and T40 groups (p<0.05). Fewer and shorter resin tags were observed in the SE, CHX, and T40 groups. A higher percentage of adhesive failure and mixed failure was found in contaminated dentin. All bonding protocols revealed lower amounts of Al and Cl after dentin contamination, except for the SE group. Conclusions: Hemostatic agent contamination adversely affected dentin bond strength. However, this bond strength could be reversed using the etch-and-rinse technique or rinsing with EDTA prior to adhesive application.

Publisher

Operative Dentistry

Subject

General Dentistry

Reference39 articles.

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3