Author:
Bayindir Yusuf Ziya,Yildiz Mehmet
Abstract
Abstract
In this study the top and bottom surface hardness of two polyacid-modified composite resins (PMCRs), one resin-modified glass ionomer cement (RMGIC), and one composite resin were evaluated. The affect of water storage on their hardness was also investigated. The study was conducted using four different groups, each having five specimens obtained from fiberglass die molds with a diameter of 5 mm and a height of 2 mm. Measurements were made on the top and bottom surface of each specimen and recorded after 24 hours and again at 60 days. All tested materials showed different hardness values, and the values of top surfaces of the specimens were found to be higher than the bottom surface in all test groups. There was no statistical difference in the Vickers hardness (HV) values when the test specimens were kept in water storage. In conclusion Hytac displayed microhardness values higher than Vitremer and Dyract. We found the order of HV values to be Surfil > Hytac > Dyract > Vitremer, respectively. Vitremer presented the lowest microhardness level and Surfil the highest.
Citation
Bayindir YZ, Yildiz M. Surface Hardness Properties of Resin-Modified Glass Ionomer Cements and Polyacid-Modified Composite Resins. J Contemp Dent Pract 2004 November;(5)4:042-049.
Publisher
Jaypee Brothers Medical Publishing
Reference60 articles.
1. Croll TP, Killian CM. Visible light-hardened glass-ionomer-resin cement restorations for primary teeth: new developments. Quintessence Int. 1992 Oct;23(10):679-82.
2. Glass Ionomer-Resin: A Maturing Concept
3. Christensen GJ. Glass ionomer-resin: a maturing concept. J Am Dent Assoc. 1993 Jul;124(7):248-9.
Cited by
14 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献