Renal Function Assessment Gap in Clinical Practice: An Awkward Truth

Author:

Trevisani Francesco,Di Marco Federico,Capitanio Umberto,Larcher Alessandro,Bettiga Arianna,Dosio Flaviano,Ghidini Michele,Del Conte Gianluca,Vago Riccardo,Cinque Alessandra,Gianolli Luigi,Salonia Andrea,Briganti Alberto,Luis-Lima Sergio,Negrín-Mena Natalia,Montorsi Francesco,Porrini Esteban

Abstract

Introduction: An accurate assessment of renal function is needed in the majority of clinical settings. Unfortunately, the most used estimated glomerular filtration rate (eGFR) formulas are affected by significant errors in comparison to gold standards methods of measured GFR (mGFR). Objective: The objective of the study is to determine the extent of the error of eGFR formulas compared to the mGFR in different specific clinical settings. Methods: A total retrospectively consecutive cohort of 1,320 patients (pts) enrolled in 2 different European Hospitals (Center 1: 470 pts; Center 2: 850 pts) was collected in order to compare the most common eGFR formulas used by physicians with the most widespread mGFR methods in daily clinical practice (Iohexol Plasma Clearance -Center 1 [mGFR-iox] and Renal Scintigraphy -Center 2 [mGFR-scnt]). The study cohort was composed by urological, oncological, and nephrological pts. The agreement between eGFR and mGFR was evaluated using bias (as median of difference), precision (as interquartile range of difference) accuracy (as P30), and total deviation index. Results: The most accurate eGFR formula in the comparison with gold standard method (Iohexol plasma clearance) in Center 1 was represented by s-creatinine and cystatin C combined Chronic Kidney Disease-Epidemiology Collaboration-cr-cy, even though the P30 is reduced (84%) under the threshold of 60 mL/min/1.73 m2. Similar results were found in Center 2, with a wider discrepancy between mGFR-scnt and eGFR formulas due to the minor accuracy of the nuclear tool in respect to the mGFR-iox. Conclusions: The loss of accuracy observed for the formulas at lower values of GFR suggests the mandatory use of gold standards methods as Iohexol Plasma Clearance to assess the correct status of renal function for critical cases. The center 2 showed lower levels of agreement between mGFR and eGFR suggesting that the errors are partially accounted for the Renal Scintigraphy technique too. In particular, we suggest the use of mGFR-iox in oncological urological and nephrological pts with an eGFR lower than 60 mL/min/1.73 m2.

Publisher

S. Karger AG

Subject

Cardiology and Cardiovascular Medicine,Nephrology,Cardiology and Cardiovascular Medicine,Nephrology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3