Accuracy of Subclassification and Grading of Renal Tumors on Fine Needle Aspiration Cytology Alone

Author:

Chen Heather I.-HsuanORCID,Lapadat Razvan,Lastra Ricardo R.,Biernacka Anna,Reeves Ward,Mueller Jeffrey,Pambuccian Stefan E.ORCID,Barkan Güliz A.,Wojcik Eva M.,Antic Tatjana

Abstract

<b><i>Background:</i></b> Fine needle aspiration (FNA) of renal masses can distinguish between benign and malignant neoplasms in 73–94% of cases. Previous studies suggested the correct subclassification of renal cell carcinomas (RCCs) by cytomorphology can be achieved in up to 80% of cases. However, as RCCs become increasingly subclassified by molecular signatures, correct subclassification based on cytology alone is increasingly difficult. <b><i>Design:</i></b> Two FNA passes (2 stained with Diff-Quik® and 2 with the Papanicolaou method) were performed on all fresh nephrectomy specimens for a 1-year period. There were 30 cases in this study, with 29 primary renal tumors and 1 case of metastatic lung adenocarcinoma. Each case was assigned a random number and came with 2 slides (1 from each staining method). Eight cytopathologists were asked to provide a diagnosis and the World Health Organization/International Society of Urological Pathology (WHO/ISUP) grading if applicable. Fleiss’ Kappa and Cohen’s Kappa equations were used to look at inter-rater variability. <b><i>Results:</i></b> When compared to the surgical pathology diagnosis, the average percent correct diagnosis for all cytopathologist was 35%. Chromophobe RCCs had the best average percent accuracy at 72% followed by clearcell RCC at 48%. Average accuracy for grading RCCs was 40%. Inter-rater variability among the cytopathologists for all RCC diagnoses was fair with a Fleiss’ Kappa coefficient of 0.28. For the WHO/ISUP grade, the weighted coefficient for each pathologist ranged from 0.11 to 0.45, ranging from fair to moderate, respectively. <b><i>Conclusions:</i></b> Renal tumors are difficult to classify on cytopathology alone. Core needle biopsy and ancillary studies are necessary if diagnosis will change management.

Publisher

S. Karger AG

Subject

General Medicine,Histology,Pathology and Forensic Medicine

Reference30 articles.

1. Nguyen GK, Akin MR. Fine needle aspiration cytology of the kidney, renal pelvis, and adrenal. Clin Lab Med. 1998;18(3):429–59, vi.

2. Dragoescu EA, Liu L. Indications for renal fine needle aspiration biopsy in the era of modern imaging modalities. Cytojournal. 2013;10:15.

3. Renshaw AA, Lee KR, Madge R, Granter SR. Accuracy of fine needle aspiration in distinguishing subtypes of renal cell carcinoma. Acta Cytol. 1997;41(4):987–94.

4. Niceforo J, Coughlin BF. Diagnosis of renal cell carcinoma: value of fine-needle aspiration cytology in patients with metastases or contraindications to nephrectomy. AJR Am J Roentgenol. 1993;161(6):1303–5.

5. Moch H, Cubilla AL, Humphrey PA, Reuter VE, Ulbright TM. The 2016 WHO classification of tumours of the urinary system and male genital organs-part a: renal, penile, and testicular tumours. Eur Urol. 2016;70(1):93–105.

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3