Pictograms, Units and Dosing Tools, and Parent Medication Errors: A Randomized Study

Author:

Yin H. Shonna12,Parker Ruth M.3,Sanders Lee M.4,Mendelsohn Alan12,Dreyer Benard P.1,Bailey Stacy Cooper5,Patel Deesha A.6,Jimenez Jessica J.1,Kim Kwang-Youn A.7,Jacobson Kara8,Smith Michelle C.J.4,Hedlund Laurie6,Meyers Nicole1,McFadden Terri9,Wolf Michael S.6

Affiliation:

1. Department of Pediatrics, New York University School of Medicine, NYC Health + Hospitals/Bellevue, New York, New York;

2. Department of Population Health, New York University School of Medicine, New York, New York;

3. Departments of Medicine and

4. Department of Pediatrics, Stanford University School of Medicine, Palo Alto, California;

5. Division of Pharmaceutical Outcomes and Policy, University of North Carolina at Chapel Hill Eshelman School of Pharmacy, Chapel Hill, North Carolina;

6. Division of General Internal Medicine and Geriatrics and

7. Department of Preventive Medicine, Northwestern University Feinberg School of Medicine, Chicago, Illinois;

8. Rollins School of Public Health, Emory University, Atlanta, Georgia

9. Pediatrics, Emory University School of Medicine, Atlanta, Georgia; and

Abstract

BACKGROUND AND OBJECTIVES: Poorly designed labels and dosing tools contribute to dosing errors. We examined the degree to which errors could be reduced with pictographic diagrams, milliliter-only units, and provision of tools more closely matched to prescribed volumes. METHODS: This study involved a randomized controlled experiment in 3 pediatric clinics. English- and Spanish-speaking parents (n = 491) of children ≤8 years old were randomly assigned to 1 of 4 groups and given labels and dosing tools that varied in label instruction format (text and pictogram, or text only) and units (milliliter-only ["mL"] or milliliter/teaspoon ["mL/tsp"]). Each parent measured 9 doses of liquid medication (3 amounts [2, 7.5, and 10 mL] and 3 tools [1 cup, 2 syringes (5- and 10-mL capacities)]) in random order. The primary outcome was dosing error (>20% deviation), and large error (>2× dose). RESULTS: We found that 83.5% of parents made ≥1 dosing error (overdosing was present in 12.1% of errors) and 29.3% of parents made ≥1 large error (>2× dose). The greatest impact on errors resulted from the provision of tools more closely matched to prescribed dose volumes. For the 2-mL dose, the fewest errors were seen with the 5-mL syringe (5- vs 10-mL syringe: adjusted odds ratio [aOR] = 0.3 [95% confidence interval: 0.2–0.4]; cup versus 10-mL syringe: aOR = 7.5 [5.7–10.0]). For the 7.5-mL dose, the fewest errors were with the 10-mL syringe, which did not necessitate measurement of multiple instrument-fulls (5- vs 10-mL syringe: aOR = 4.0 [3.0–5.4]; cup versus 10-mL syringe: aOR = 2.1 [1.5–2.9]). Milliliter/teaspoon was associated with more errors than milliliter-only (aOR = 1.3 [1.05–1.6]). Parents who received text only (versus text and pictogram) instructions or milliliter/teaspoon (versus milliliter-only) labels and tools made more large errors (aOR = 1.9 [1.1–3.3], aOR = 2.5 [1.4–4.6], respectively). CONCLUSIONS: Provision of dosing tools more closely matched to prescribed dose volumes is an especially promising strategy for reducing pediatric dosing errors.

Publisher

American Academy of Pediatrics (AAP)

Subject

Pediatrics, Perinatology, and Child Health

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3