Alterations in membrane stability after in vitro exposure of human erythrocytes to 2.41 GHz electromagnetic field

Author:

Angelova BoyanaORCID,Atanasova GabrielaORCID,Atanasov NikolayORCID,Paunov Momchil,Gurmanova Maria,Kouzmanova MargaritaORCID

Abstract

The growing use of wireless communication devices has been significantly increasing the level of high frequency electromagnetic fields (EMFs) in the environment, which raises a concern for possible deleterious effects on living organisms. Long lasting exposure to low-intensity EMFs can cause effects on the molecular and cellular level, and a number of morphological and physiological changes. The aim of this work was to investigate the effects of 2.41 GHz EMF emitted by wireless communication systems on human erythrocytes after in vitro irradiation. The amount of the hemoglobin released from the cells was measured as an indicator for membrane destabilization. Effects of different exposure times (20 min or 4 h) and time elapsed after exposure to 2.41 GHz pulsed or continuous EMFs with different intensities, emitted from a textile (0.213–0.238 V/m) or a dipole (5, 20, 40 and 180 V/m) antenna, were investigated. The obtained results showed that the low intensity EMF had no significant effect on the hemoglobin release from irradiated cells; even a slight tendency for membrane stabilization was noticed 3–4 hours after the end of 20-min exposure to 0.213–0.238 V/m, 2.41 GHz EMF. There was no difference in the effects of continuous and pulsed EMFs. Increased hemoglobin release was observed only during the 4-hour exposure to 180 V/m, 2.41 GHz continuous EMF. Under these conditions, the temperature of the cell suspension had been rising, so we compared the results obtained under EMF with the effects of conventional heating. Moreover, after 1-hour exposure to 180 V/m the released hemoglobin level was a bit higher than the control one but the difference disappears within an hour after terminating the irradiation. In conclusion, the in vitro exposure to 2.41 GHz EMF emitted by wireless communication devices with power density below the reference level for population exposure does not change the stability of the cell membrane of human erythrocytes.

Publisher

Pensoft Publishers

Subject

Environmental Science (miscellaneous)

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3