Intercomparison of Water Vapor Data Measured with Lidar during IHOP_2002. Part II: Airborne-to-Airborne Systems

Author:

Behrendt Andreas1,Wulfmeyer Volker1,Schaberl Thorsten1,Bauer Hans-Stefan1,Kiemle Christoph2,Ehret Gerhard2,Flamant Cyrille3,Kooi Susan4,Ismail Syed4,Ferrare Richard4,Browell Edward V.4,Whiteman David N.5

Affiliation:

1. Institut für Physik und Meteorologie, Universität Hohenheim, Stuttgart, Germany

2. Deutsches Zentrum für Luft- und Raumfahrt (DLR), Oberpfaffenhofen, Germany

3. CNRS Service Aéronomie, Université Pierre et Marie Curie, Paris, France

4. NASA Langley Research Center, Hampton, Virginia

5. Mesoscale Atmospheric Processes Branch, NASA GSFC, Greenbelt, Maryland

Abstract

Abstract The dataset of the International H2O Project (IHOP_2002) gives the first opportunity for direct intercomparisons of airborne water vapor lidar systems and allows very important conclusions to be drawn for future field campaigns. Three airborne differential absorption lidar (DIAL) systems were operated simultaneously during some IHOP_2002 missions: the DIAL of Deutsches Zentrum für Luft- und Raumfahrt (DLR), the Lidar Atmospheric Sensing Experiment (LASE) of the National Aeronautics and Space Administration (NASA) Langley Research Center, and the Lidar Embarque pour l’etude des Aerosols et des Nuages de l’interaction Dynamique Rayonnement et du cycle de l’Eau (LEANDRE II) of the Centre National de la Recherche Scientifique (CNRS). Data of one formation flight with DLR DIAL and LEANDRE II were investigated, which consists of 54 independent profiles of the two instruments measured with 10-s temporal average. For the height range of 1.14–1.64 km above sea level, a bias of (−0.41 ± 0.16) g kg−1 or −7.9% ± 3.1% was found for DLR DIAL compared to LEANDRE II (LEANDRE II drier) as well as root-mean-square (RMS) deviations of (0.87 ± 0.18) g kg−1 or 16.9% ± 3.5%. With these results, relative bias values of −9.3%, −1.5%, +2.7%, and +8.1% result for LEANDRE II, DLR DIAL, the scanning Raman lidar (SRL), and LASE, respectively, using the mutual bias values determined in Part I for the latter three sensors. From the three possible profile-to-profile intercomparisons between DLR DIAL and LASE, one case cannot provide information on the system performances due to very large inhomogeneity of the atmospheric water vapor field, while one of the two remaining two cases showed a difference of −4.6% in the height range of 1.4–3.0 km and the other of −25% in 1.3–3.8 km (in both cases DLR DIAL was drier than LASE). The airborne-to-airborne comparisons showed that if airborne water vapor lidars are to be validated down to an accuracy of better than 5% in the lower troposphere, the atmospheric variability of water vapor has to be taken into account down to scales of less than a kilometer unless a sufficiently large number of intercomparison cases is available to derive statistically solid biases and RMS deviations. In conclusion, the overall biases between the water vapor data of all three airborne lidar systems operated during IHOP_2002 are smaller than 10% in the present stage of data evaluation, which confirms the previous estimates of the instrumental accuracies for all the systems.

Publisher

American Meteorological Society

Subject

Atmospheric Science,Ocean Engineering

Reference32 articles.

1. Temperature measurements with lidar.;Behrendt,2005

2. Combining water vapor DIAL and rotational Raman temperature lidar for humidity, temperature, and particle measurements with high resolution and accuracy.;Behrendt,2003

3. Behrendt, A., C.Kiemle, P.Di Girolamo, H-S.Bauer, T.Schaberl, and V.Wulfmeyer, 2004a: Measurement and intercomparison of active, passive, and in-situ-sensors during the International H2O Project for the verification of the specifications of the WALES experiment. Second Tech. Note ESTEC Contract 16669/02/NL/FF, 115 pp.

4. Behrendt, A., C.Kiemle, P.Di Girolamo, H-S.Bauer, T.Schaberl, and V.Wulfmeyer, 2004b: Measurement and intercomparison of active, passive, and in-situ-sensors during the International H2O Project for the verification of the specifications of the WALES experiment. Final Rep. ESTEC Contract 16669/02/NL/FF, 56 pp.

5. Intercomparison of water vapor data measured with lidar during IHOP_2002. Part I: Airborne to ground-based lidar systems and comparisons with chilled-mirror hygrometer radiosondes.;Behrendt;J. Atmos. Oceanic Technol.,2007

Cited by 32 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3