Prognostic value and reproducibility of measurements of carotid stenosis. A comparison of three methods on 1001 angiograms. European Carotid Surgery Trialists' Collaborative Group.

Author:

Rothwell P M1,Gibson R J1,Slattery J1,Warlow C P1

Affiliation:

1. Department of Clinical Neurosciences, Western General Hospital, Edinburgh, Scotland.

Abstract

The use of three methods of measuring carotid stenosis, which produce different values on the same angiograms, has caused confusion and reduced the generalizability of the results of research. If the results of future studies are to be properly applied to clinical practice, and if noninvasive methods of imaging are to be properly validated against angiography, a single, standard method of measurement of stenosis on angiograms must be adopted. This standard method should be selected on the bases of its ability to predict risk of ipsilateral carotid distribution ischemic stroke and its reproducibility. The method of measurement of carotid stenosis used in the European Carotid Surgery Trial (ECST), that used in the North American Symptomatic Carotid Endarterectomy Trial (NASCET), and a method based on the measurement of the common carotid (CC) lumen diameter were studied. Their use in the prediction of ipsilateral carotid distribution ischemic stroke was assessed in 1001 consecutively selected patients randomly assigned to medical treatment in the ECST. Carotid stenosis was measured by two observers working independently, using all three methods, on the angiographic view that showed the most severe stenosis of the symptomatic carotid bifurcation. Interobserver agreement was determined, and 50 angiograms were remeasured to determine intraobserver agreement. There was little difference in the ability of the three methods to predict ipsilateral carotid distribution ischemic stroke. The CC method was consistently the most reproducible of the three, particularly for stenosis in the clinically important range of 50% to 90%. The CC method of measurement should be adopted as the standard method of measuring the degree of carotid stenosis on angiograms.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Advanced and Specialized Nursing,Cardiology and Cardiovascular Medicine,Neurology (clinical)

Cited by 152 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3