Preclinical Direct Endoluminal Assessment of Endothelialization After Flow Diversion With Microangioscopy

Author:

Srinivasan Visish M.1ORCID,Garcia Roberto L.2,Shekhtman Oleg1,Robledo Ariadna2,Lazaro Tyler3,Rao Abhijit2,O'Leary Sean2,Husain Adam2,Covell Michael M.4,Phillips Michael5,Cooper Phillip5,Duncan Richard Forrest6,Bolanos Oscar6,Colasurdo Marco5,Edhayan Gautam2,Chen Stephen R.7,Fahed Robert89,Kan Peter2

Affiliation:

1. Department of Neurosurgery University of Pennsylvania Philadelphia PA

2. Department of Neurosurgery University of Texas Medical Branch Galveston TX

3. Department of Neurosurgery Baylor College of Medicine Houston TX

4. School of Medicine Georgetown University Washington DC

5. Vena Medical Kitchener Ontario Canada

6. Neurovascular Division Medtronic Irvine CA

7. Department of Interventional Radiology The MD Anderson Cancer Center Houston TX

8. Department of Medicine Division of Neurology Ottawa Hospital Ontario Canada

9. Ottawa Hospital Research Institute University of Ottawa Ontario Canada

Abstract

Background Direct endoluminal imaging, such as with our previously described microangioscope, is an emerging adjunct in endovascular cerebral aneurysm management that enables clinicians to delineate between thrombi and visualize neoepithelialization after stent placement with high resolution. The present study sought to study flow diversion in vivo under direct endoluminal imaging, and to validate our findings with histopathology. Methods In a rabbit model, we implanted each left common carotid artery with a shielded flow diverter (FD) (Medtronic Pipeline Vantage) and nonshielded FD (Medtronic Pipeline Flex) in the right common carotid artery. We studied 9 animals in 3 groups: (1) no periprocedural antiplatelet therapy, (2) aspirin 81 mg daily, and (3) aspirin 81 mg and clopidogrel 75 mg daily. FD thrombosis, stenosis, malapposition, and neoepithelialization were all evaluated by diagnostic cerebral angiography and microangioscopy after 30 days. Diagnostic cerebral angiography and angioscopic video were analyzed by independent evaluators and compared with histopathologic analysis. Results In the aspirin and dual antiplatelet therapy groups, there were no significant observed differences in stent thrombosis, stenosis, malapposition, or neoepithelialization between the shielded and non‐shielded FD groups. There was significantly more thrombus formation in Group 1. Neointimal thickness as measured by the microangioscope was highly correlated with histology (r = 0.72; P = 0.016). Interrater agreement of microangioscope videos was highest for FD thrombosis and stenosis. Conclusion In‐stent thrombosis, stenosis, malapposition, and neopithelialization demonstrated no significant difference between shielded and non‐shielded FDs. Microangioscopy measurements for neointimal thickness were highly correlated with pathology and may be a helpful adjunct to diagnostic cerebral angiography in FD follow‐up.

Publisher

Ovid Technologies (Wolters Kluwer Health)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3