Assessment of an ECG‐Based System for Localizing Ventricular Arrhythmias in Patients With Structural Heart Disease

Author:

Zhou Shijie1ORCID,AbdelWahab Amir2ORCID,Sapp John L.23ORCID,Sung Eric14ORCID,Aronis Konstantinos N.54ORCID,Warren James W.3,MacInnis Paul J.3,Shah Rushil5ORCID,Horáček B. Milan6,Berger Ronald15ORCID,Tandri Harikrishna15ORCID,Trayanova Natalia A.14ORCID,Chrispin Jonathan15ORCID

Affiliation:

1. Alliance for Cardiovascular Diagnostic and Treatment Innovation Johns Hopkins University Baltimore MD

2. Department of Medicine Queen Elizabeth II Health Sciences Centre Halifax NS Canada

3. Department of Physiology and Biophysics Dalhousie University Halifax NS Canada

4. Department of Biomedical Engineering Johns Hopkins University Baltimore MD

5. Division of Cardiology Department of Medicine Section of Cardiac Electrophysiology Johns Hopkins Hospital Baltimore MD

6. School of Biomedical Engineering Dalhousie University Halifax NS Canada

Abstract

Background We have previously developed an intraprocedural automatic arrhythmia‐origin localization (AAOL) system to identify idiopathic ventricular arrhythmia origins in real time using a 3‐lead ECG. The objective was to assess the localization accuracy of ventricular tachycardia (VT) exit and premature ventricular contraction (PVC) origin sites in patients with structural heart disease using the AAOL system. Methods and Results In retrospective and prospective case series studies, a total of 42 patients who underwent VT/PVC ablation in the setting of structural heart disease were recruited at 2 different centers. The AAOL system combines 120‐ms QRS integrals of 3 leads (III, V2, V6) with pace mapping to predict VT exit/PVC origin site and projects that site onto the patient‐specific electroanatomic mapping surface. VT exit/PVC origin sites were clinically identified by activation mapping and/or pace mapping. The localization error of the VT exit/PVC origin site was assessed by the distance between the clinically identified site and the estimated site. In the retrospective study of 19 patients with structural heart disease, the AAOL system achieved a mean localization accuracy of 6.5±2.6 mm for 25 induced VTs. In the prospective study with 23 patients, mean localization accuracy was 5.9±2.6 mm for 26 VT exit and PVC origin sites. There was no difference in mean localization error in epicardial sites compared with endocardial sites using the AAOL system (6.0 versus 5.8 mm, P =0.895). Conclusions The AAOL system achieved accurate localization of VT exit/PVC origin sites in patients with structural heart disease; its performance is superior to current systems, and thus, it promises to have potential clinical utility.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3