Abstract 17046: Accuracy of Apple Watch for Detection of Atrial Fibrillation: A Systematic Review and Meta-Analysis

Author:

Yasmin Farah1,Moeed Abdul2,Adil Mariam3,Rahman Saad Ur4,Wilson F. Perry1

Affiliation:

1. Yale Univ Sch of Medicine, New Haven, CT

2. Dow Med College, Karachi, Sindh, Pakistan

3. Dow Med College, Karachi, Pakistan

4. Carle Foundation Hosp, Urbana, IL

Abstract

Background: Apple Watch (AW) for the detection of silent atrial fibrillation (AF) has shown encouraging results due to its photoplethysmogram (PPG) sensors. However, clinical accuracy studies show varying results. To the best of our knowledge, this is the first meta-analysis conducted to ascertain the pooled sensitivity, and specificity in AF detection using the AW. Methods: PubMed, Google Scholar, and Scopus were queried till May 2023 for studies examining the accuracy of AW in AF detection. The outcomes of interest were the sensitivity and specificity of AW for the detection of AF. Sensitivities and specificities were calculated using true positives, true negatives, false positives, and false negatives wherever applicable. A random-effects meta-analysis was conducted using the generic inverse variance method to pool sensitivities and specificities. Further, sensitivity analysis was performed excluding studies using KardiaBand. Results: A total of 12 studies with a patient population of 421,156 were included with a mean age of 63 years. 6/12 studies used AW series 4 or higher while 3/12 studies evaluated the use of KardiaBand on top of the AW. AF was detected in 3,184 patients from a total of 420,312 patients. Following pooled analysis, an overall point estimate of sensitivity was observed to be [0.87 (0.76, 0.98); Figure 1A]. Ten studies evaluated specificity, with the pooled estimate being [0.91 (0.87, 0.95); Figure 1B]. After excluding studies using KardiaBand, the sensitivity was reported as 0.84 [0.68, 1.00] and specificity was observed to be 0.94 [0.91, 0.98]. Conclusion: AW proved to be effective in detecting AF in our analysis owing to high overall sensitivity and specificity with and without the addition of KardiaBand. However, cardiologists should still exercise caution before undertaking action based on the electrocardiographic diagnosis generated by this wrist-worn monitor.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3