Fluorescent Cardiac Imaging

Author:

Detter Christian1,Wipper Sabine1,Russ Detlef1,Iffland Andre1,Burdorf Lars1,Thein Eckart1,Wegscheider Karl1,Reichenspurner Hermann1,Reichart Bruno1

Affiliation:

1. From the Department of Cardiovascular Surgery, University Heart Center Hamburg, Hamburg (C.D., S.W., H.R.); Institut für Lasertechnologien in der Medizin und Messtechnik, University Ulm, Ulm (D.R., A.I.); Department of Cardiac Surgery (L.B., B.R.) and Institute for Surgical Research (E.T.), Ludwig-Maximilians University, Munich; and Department of Medical Biometry and Epidemiology, University Hospital Eppendorf, Hamburg (K.W.), Germany.

Abstract

Background— The purpose of the present study was to examine whether the effect of coronary stenoses of variable severity on myocardial perfusion can be quantitatively assessed in vivo by analysis of fluorescent cardiac imaging (FCI) compared with the gold standard, the fluorescent microsphere method. FCI is a novel technology to visualize coronary vessels and myocardial perfusion intraoperatively using the indocyanine green dye with an infrared-sensitive imaging device. Methods and Results— Graded stenoses and total vessel occlusion of the left anterior descending coronary artery were created in 11 open-chest pigs. Stenoses were graded to reduce resting left anterior descending coronary artery flow by 25%, 50%, 75%, and 100% of baseline flow measured by transit-time flowmeter. FCI images were analyzed with a digital image processing system. The impairment of myocardial perfusion was quantified by background-subtracted peak fluorescence intensity and slope of fluorescence intensity obtained with FCI and compared with myocardial blood flow assessed by fluorescent microsphere. All stenoses resulted in an impairment of myocardial perfusion visualized by FCI. Occlusion of the left anterior descending coronary artery resulted in a total perfusion defect (no fluorescence intensity) of the corresponding anterior myocardial wall. During graded stenosis and total vessel occlusion, normalized background-subtracted peak fluorescence intensity and slope of fluorescence intensity decreased significantly ( P <0.0001). Both background-subtracted peak fluorescence intensity ( r =0.92, P <0.0001) and slope of fluorescence intensity ( r =0.93, P <0.0001) analyzed by FCI demonstrated good linear correlation with fluorescent microsphere–derived myocardial blood flow. Conclusions— The impairment of myocardial perfusion in response to increased coronary stenosis severity and total vessel occlusion can be quantitatively assessed by FCI and correlates well with results obtained by fluorescent microsphere.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3