Arterial Spin–Labeled Perfusion Imaging to Predict Mismatch in Acute Ischemic Stroke

Author:

Niibo Takeya1,Ohta Hajime1,Yonenaga Kazuma1,Ikushima Ichiro1,Miyata Shirou1,Takeshima Hideo1

Affiliation:

1. From the Department of Neurosurgery, Miyakonojo Regional Medical Center (T.N.); Department of Neurosurgery, Miyakonojo Medical Association Hospital (H.O.); Department of Radiology (K.Y., I.I.), and Department of Neurosurgery (S.M.), Miyakonojo Regional Medical Center; and Department of Neurosurgery, Faculty of Medicine, University of Miyazaki (H.T.), Miyazaki, Japan.

Abstract

Background and Purpose— We assigned a threshold to arterial spin–labeling (ASL) perfusion-weighted images (PWI) from patients with acute ischemic stroke and compared them with dynamic susceptibility contrast perfusion images to examine whether mismatch can be determined. Methods— Pseudocontinuous ASL was combined with dynamic susceptibility contrast PWI in 23 patients with acute ischemic stroke. Scans were obtained within 24 hours of symptom onset. PWI volumes were defined by ASL cerebral blood flow (<15, <20, and <25 mL/100 g per minute) and dynamic susceptibility contrast–mean transit time (MTT) thresholds (>10 s) that show a strong association with cerebral blood flow <20 mL/100 g per minute in Xenon CT studies. Agreement between the ASL–diffusion-weighted imaging and MTT–diffusion-weighted imaging mismatch and the correlation between penumbra salvage and infarct growth, defined as the difference between the baseline PWI and the baseline diffusion-weighted imaging lesion, respectively, and the final infarct volume were assessed. Results— The lesion volumes defined by MTT>10 s and ASL<20 mL/100 g per minute showed an excellent correlation. There was 100% agreement on the mismatch status between MTT>10 s and ASL<20 mL/100 g per minute. The correlation between infarct growth and penumbra salvage volume was significantly better for PWI lesions defined by ASL<20 mL/100 g per minute and MTT>10 s. Conclusions— In acute ischemic stroke, PWI lesions based on ASL threshold of <20 mL/100 g per minute can provide a reliable estimate of mismatch in correspondence at MTT threshold of >10 s.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Advanced and Specialised Nursing,Cardiology and Cardiovascular Medicine,Clinical Neurology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3