Multidelay Arterial Spin Labeling Versus Computed Tomography Perfusion in Penumbra Volume of Acute Ischemic Stroke

Author:

Yan Chuming1ORCID,Yu Fan2,Zhang Yingjie1,Zhang Miao2,Li Jingkai2ORCID,Wang Zixin1,Lu Jie2ORCID,Ma Qingfeng1ORCID

Affiliation:

1. Department of Neurology (C.Y., Y.Z., Z.W., Q.M.), Xuanwu Hospital Capital Medical University, Beijing, China.

2. Department of Radiology (F.Y., M.Z., J.L., J.L.), Xuanwu Hospital Capital Medical University, Beijing, China.

Abstract

Background: Multidelay arterial spin labeling (ASL) is a novel perfusion method of ASL, with arterial transit time (ATT) calculated by multiple postlabeling delays to correct cerebral blood flow (CBF). We verify the accuracy of multidelay ASL in evaluating the ischemic penumbra and perfusion levels in patients with acute ischemic stroke, compared with computed tomography perfusion (CTP). Methods: Patients with acute ischemic stroke with anterior circulation large vessel occlusion received baseline CTP, multidelay ASL, and diffusion-weighted imaging (DWI) in succession. Multidelay ASL image was processed to reconstruct ATT, CBF without ATT correction, and CBF corrected by ATT. The consistency of hypoperfusion and ischemic penumbra volume calculated by CTP and multidelay ASL were quantified by intraclass correlation coefficient (ICC) in 2-way mixed effects, absolute agreement, and single measure. Wilcoxon signed-rank test was used to compare the difference in penumbra volume between CTP, corrected ASL, and uncorrected ASL. Results: Thirty patients were included. Hypoperfusion volume based on multidelay ASL with different thresholds were 117.95 (87.77–151.49) mL for corrected relative CBF<40%, 130.29 (85.99–249.37) mL for CBF corrected by ATT<20 mL·100g -1 ·min -1 , no statistical difference ( P >0.05) compared with the volume of CTP, and consistency was almost excellent (ICC, 0.91) and substantial consistent (ICC, 0.727). The volumes of ischemic penumbra were 91.00 (42.68–125.27) mL for corrected relative CBF<40%-DWI, 108.94 (62.03–150.86) mL for CBF corrected by ATT<20 mL·100 g -1 ·min -1 -DWI, which showed no statistical difference compared with the penumbra volume of CTP ( P >0.05). The consistency was excellent (ICC, 0.822) and moderate (ICC, 0.501), respectively. The volume of uncorrected relative CBF <40%-DWI was 209.57 (123.21–292.45) mL, statistically larger than corrected relative CBF <40%-DWI ( P <0.001) and CTP ( P <0.001). The volume of uncorrected CBF<20 mL·100g -1 ·min -1 -DWI was 186.23 (86.56–298.22) mL, statistically larger than CBF corrected by ATT<20 mL·100g -1 ·min -1 -DWI ( P <0.001) and CTP( P <0.001). Conclusions: The volume of ischemic penumbra determined by CBF/DWI mismatch based on multidelay ASL is consistent with CTP. The penumbra volume calculated by CBF adjusted by ATT is more accurate.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Advanced and Specialized Nursing,Cardiology and Cardiovascular Medicine,Neurology (clinical)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3