New Generation of Flow Diverter (Surpass) for Unruptured Intracranial Aneurysms

Author:

De Vries Joost1,Boogaarts Jeroen1,Van Norden Anouk1,Wakhloo Ajay K.1

Affiliation:

1. From the Departments of Neurosurgery (J.D.V., J.B.) and Neurology (A.V.N.), Radboud University Nijmegen Medical Center, Nijmegen, The Netherlands; and Department of Radiology (A.K.W.), University of Massachusetts Medical School, Worcester, MA.

Abstract

Background and Purpose— In patients harboring intracranial aneurysms, the major goal in treatment is to prevent bleeding. A new generation of an endoluminal device (Surpass Flow Diverter [Surpass]) was developed to reconstruct parent artery and occlude the aneurysm. We present our clinical and angiographic single-center experience. Methods— Patients with a wide range of complex unruptured aneurysms were treated with the Surpass placed in the parent artery and bridging the aneurysm. Clinical and angiographic follow-up were performed at 6 months. Data were prospectively collected. Results— Thirty seven patients (mean age, 56 years; range, 32–79), harboring 49 unruptured aneurysms were treated at our center. All except 1 patient were treated with a single device. Successful delivery of the device was achieved in all patients. All 35 nonbifurcation aneurysm necks were covered completely, whereas 14 bifurcation aneurysms were only partially covered. There was no major periprocedural morbidity or mortality. During follow-up, 4 patients (10.4%) experienced transient neurological deficit. One patient (3%) developed a minor stroke at 4-month follow-up with persistent neurological deficit. Twelve patients had neurological symptoms related to their aneurysm and 7 showed improvement of these symptoms during follow-up. At 6-month follow-up, 29 of 31 aneurysms studied that had complete neck coverage showed a complete occlusion (94%) including 1 case with a 95% to 100% occlusion, whereas 5 of the 10 bifurcation aneurysms were occluded. Conclusions— Our study shows high safety and efficacy profile of a new generation endoluminal device in treatment of complex intracranial aneurysms. Long-term studies of treated bifurcation aneurysms are needed.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Advanced and Specialised Nursing,Cardiology and Cardiovascular Medicine,Clinical Neurology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3