Framingham Stroke Risk Function in a Large Population-Based Cohort of Elderly People

Author:

Bineau Sébastien1,Dufouil Carole1,Helmer Catherine1,Ritchie Karen1,Empana Jean-Philippe1,Ducimetière Pierre1,Alpérovitch Annick1,Bousser Marie Germaine1,Tzourio Christophe1

Affiliation:

1. From INSERM U708 “Neuroepidemiology” (S.B., C.D., A.A., C.T.), Paris; UPMC Univ Paris 06 (S.B., C.D., A.A., C.T.), Paris; INSERM U593 and Université Bordeaux 2 (C.H.), Bordeaux; INSERM U888 (K.R.), Montpellier; INSERM U909 (J.-P.E., P.D.), Villejuif; and the Department of Neurology (M.G.B., C.T.), Hôpital Lariboisière, Paris, France.

Abstract

Background and Purpose— External validation of the Framingham stroke risk function has been rarely performed. We assessed its predictive ability in a population-based cohort of French elderly. Methods— The sample comprised 6913 subjects from the 3C Study, aged 65 to 84 at baseline, who were followed up to 6 years. Predictive accuracy of the original Framingham stroke risk function was assessed in a 3-step procedure: comparison between the Framingham and 3C cohorts of the prevalence of selected risk factors and the associated relative risks (RR) for stroke, comparison of the predicted to the observed number of stroke events (calibration), and ability to separate high-risk from low-risk participants (discrimination). We also compared predictive performances of the original Framingham, the recalibrated Framingham, and the local stroke risk functions. Results— During follow-up, 110 incident strokes occurred. For most risk factors, RRs were comparable between the 2 cohorts, except for age in women. The original Framingham stroke risk function applied to the 3C cohort overestimated the 6-year absolute risk for stroke by a factor of 3.7 for men and 4.4 for women. However, the recalibrated Framingham and 3C functions did not show any over- or underestimation of stroke risk. The 3 stroke risk functions (original, recalibrated, and 3C) provided acceptable discrimination with areas under the ROC curve ranging from 0.67 to 0.73. Conclusions— The original Framingham stroke risk function strongly overestimated the stroke risk for 3C participants. Derived Framingham stroke score sheets should not be directly used by physicians in the French elderly population.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Advanced and Specialized Nursing,Cardiology and Cardiovascular Medicine,Neurology (clinical)

Cited by 41 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3