Postextrasystolic potentiation and its contribution to the beat-to-beat variation of the pulse during atrial fibrillation.

Author:

Hardman S M1,Noble M I1,Seed W A1

Affiliation:

1. Academic Unit of Cardiovascular Medicine, Charing Cross and Westminster Medical School, London.

Abstract

BACKGROUND Beat-to-beat variations in the pulse during atrial fibrillation (AF) have conventionally been attributed to time-dependent changes in filling. We have explored the possibility that they are dependent on the intrinsic myocardial interval force relation. METHODS AND RESULTS Left ventricular (LV) contractility (maximum rate of rise of pressure, LV dP/dtmax) and ascending aortic blood velocity were measured during cardiac catheterization in 15 patients with AF. Beats preceded by an interval of less than 500 msec were excluded from analysis to reduce the confounding influence of incomplete mechanical restitution. The LV dP/dtmax was then related to the prepreceding interval. An inverse relation consistent with postextrasystolic potentiation was obtained in all 15 patients (Spearman's rank correlations, -0.56 to -0.86; p less than or equal to 0.0001). This relation was confirmed in three patients during pacing that overrode the AF and introduced single-interval variations into steady-state pacing. The ECG sequences from six of the AF patients were used to drive isometrically contracting guinea pig papillary muscle and human right ventricular tissue (n = 7); the same inverse relation was demonstrated. On a beat-by-beat basis, the maximum rate of rise of force in the isolated muscle correlated well with LV dP/dtmax in the patients (r = 0.50-0.86, p less than or equal to 0.0001). The relation of the integral of aortic velocity (AVI, proportional to stroke volume) to prepreceding interval was also inverse, whereas important correlations were demonstrated between LV dP/dtmax and AVI (Spearman's rank correlations, 0.27-0.95; p less than or equal to 0.0001). CONCLUSIONS This study demonstrates that postextrasystolic potentiation contributes to the characteristic beat-to-beat variation of the pulse in AF.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 56 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3